Schneider Electric · Harmony XB4 ATEX 系列

XB4-BS8445

在产
ATEX IECEX CE

ATEX Emergency Stop Twist Release

零件编号: B - S - 844
Schneider Electric Harmony XB4 ATEX 系列 Introduced circa 2008
Schneider Electric XB4-BS8445 — ATEX Emergency Stop Twist Release

ATEX-certified 40mm mushroom emergency stop for hazardous areas.

常见应用

Critical safety device on oil drilling platforms, gas compressor stations, and chemical reactors. ATEX Zone 1 certification ensures the e-stop itself cannot become an ignition source. Twist-to-release prevents accidental restart in hazardous environments.

规格参数

Actuator Function
Twist-to-release
Actuator Type
Mushroom 40mm
ATEX Zone
Zone 1, Zone 21
Certifications
ATEX, IECEx, CE
Color
Red
Contact Configuration
1NC
Cutout Diameter
22mm
Explosion Group
IIC
IP Rating
IP66
Temperature Class
T6

带有此图标的规格参数链接到制造商的原始来源页面

您还需要

这是一个模块化组件。要完成组装,您可能还需要:

兼容替代品

这些产品是来自其他制造商的功能等效互换产品。

安装快速参考

Panel cutout: 22mm. Mount with the yellow backing plate visible (required by EN/ISO 13850).

Wiring: Wire NC contacts in series with the safety relay input channels. Use dual-channel wiring for SIL 3 / PLe applications. Never wire directly to a motor contactor.

Testing: Press the e-stop and verify the machine stops within the required time. Test the reset mechanism. Repeat monthly per EN/ISO 13850.

尺寸

Front 22mm cutout 40mm head Side panel terminals

接线图

L T 21 22 NC (closed) opens on press

故障排除

E-stop won't reset (twist/pull doesn't release)

Check for debris in the mechanism. For twist-release: turn clockwise 45-90 degrees. For push-pull: pull straight out firmly. If the mechanism is stuck, the internal latch may be damaged — replace the entire head assembly.

Machine doesn't stop when e-stop is pressed

Critical safety issue. Immediately lock out the machine. Check wiring — NC contacts must be in series with the safety relay. Verify the safety relay is functioning. A broken wire in an NC circuit should cause a stop, so check for a wiring bypass.

Safety relay faults after e-stop reset

The safety relay detects a cross-fault between the two monitoring channels. Check that both NC contacts on the e-stop are switching simultaneously. One contact may be welded closed — replace the contact block.

快速规格

Actuator Function
Twist-to-release
Actuator Type
Mushroom 40mm
ATEX Zone
Zone 1, Zone 21
Certifications
ATEX, IECEx, CE
Color
Red

用户评价

+

“XB4-BS8445 meets EN/ISO 13850 requirements. Always wire NC contacts through a safety relay, never direct to contactor. Test monthly.”

Reddit r/PLC 26 点赞 查看讨论 →