Schneider Electric · Harmony XALK Series

XALK178E

Active
UL CSA CE

Schneider Harmony XALK Emergency-Stop Station (yellow, red mushroom, XALK178E)

Schneider Electric Harmony XALK Series Introduced circa 2003

Schneider Harmony XALK single-button control station — enclosed.

Common Applications

Complete control station: green start button in a sealed IP65 enclosure. Mounts on a wall or machine frame. No panel cutout needed. Pre-wired with cable gland. For remote start stations on conveyor lines, pump stations, and loading docks.

Specifications

Certifications
UL, CSA, CE
Color
Yellow enclosure, red mushroom head
Contact Configuration
NC (emergency-stop) — commonly 1NC; verify count. NOT 1NO
Function
Emergency stop (E-STOP)
IP Rating
IP65
Material
Polycarbonate enclosure
Mounting Type
Surface mount (enclosed)
Operator
1x red Ø40 mushroom-head emergency stop (turn/pull to release), XB5 system
Pn note
Corrected: XALK178E = yellow enclosure + red mushroom EMERGENCY STOP station (se.com/Mouser). Was mislabeled green 1-button START station / 1NO. E-stop uses NC contacts.
Pn status
mislabel-corrected

Installation Quick Reference

Panel cutout: 22mm. Insert from the front of the panel, secure with mounting nut from behind (tighten to 2-3 Nm).

Contact block: Snap or screw the contact block onto the rear of the button body. Ensure the contact block orientation matches the wiring diagram — NO terminals are usually marked.

Wiring: Use 0.5-2.5mm² stranded wire with ferrules. Tighten screw terminals to 0.8 Nm. Test the button function before energizing the circuit.

Dimensions

Wiring Diagram

11 12 NO 21 22 NC

Troubleshooting

Button doesn't respond when pressed

Check the contact block first — it's the most common failure point. Test continuity across the NO or NC terminals with a multimeter. If no click is felt, the return spring in the head may be broken.

Works intermittently

Contact block contacts are pitted or burned. Replace the contact block — don't try to file the contacts. Check if the rated cycle count has been exceeded.

Button feels mushy or doesn't click

The spring return mechanism in the button head is worn. Replace the head. The contact block can usually be reused if it tests OK.

Quick Specs

Certifications
UL, CSA, CE
Color
Yellow enclosure, red mushroom head
Contact Configuration
NC (emergency-stop) — commonly 1NC; verify count. NOT 1NO
Function
Emergency stop (E-STOP)
IP Rating
IP65

What People Are Saying

+

“Complete control station: green start button in a sealed IP65 enclosure. Mounts on a wall or machine frame. No panel cutout needed. Pre-wired with cable gland. For remote start stations on conveyor li”