Schneider Electric · Harmony XB4 ATEX 시리즈

XB4-BS8445

현행 제품
ATEX IECEX CE

ATEX Emergency Stop Twist Release

부품 번호: B - S - 844
Schneider Electric Harmony XB4 ATEX 시리즈 Introduced circa 2008
Schneider Electric XB4-BS8445 — ATEX Emergency Stop Twist Release

ATEX-certified 40mm mushroom emergency stop for hazardous areas.

일반적인 용도

Critical safety device on oil drilling platforms, gas compressor stations, and chemical reactors. ATEX Zone 1 certification ensures the e-stop itself cannot become an ignition source. Twist-to-release prevents accidental restart in hazardous environments.

사양 목록

Actuator Function
Twist-to-release
Actuator Type
Mushroom 40mm
ATEX Zone
Zone 1, Zone 21
Certifications
ATEX, IECEx, CE
Color
Red
Contact Configuration
1NC
Cutout Diameter
22mm
Explosion Group
IIC
IP Rating
IP66
Temperature Class
T6

이 아이콘이 있는 사양은 제조사의 원본 출처 페이지에 연결되어 있습니다

추가로 필요한 부품

이것은 모듈형 부품입니다. 완전한 조립을 위해 다음이 추가로 필요할 수 있습니다:

호환 대체품

이 제품들은 다른 제조사의 기능적으로 동등한 호환품입니다.

설치 빠른 참조

Panel cutout: 22mm. Mount with the yellow backing plate visible (required by EN/ISO 13850).

Wiring: Wire NC contacts in series with the safety relay input channels. Use dual-channel wiring for SIL 3 / PLe applications. Never wire directly to a motor contactor.

Testing: Press the e-stop and verify the machine stops within the required time. Test the reset mechanism. Repeat monthly per EN/ISO 13850.

외형 치수

Front 22mm cutout 40mm head Side panel terminals

배선도

L T 21 22 NC (closed) opens on press

문제 해결

E-stop won't reset (twist/pull doesn't release)

Check for debris in the mechanism. For twist-release: turn clockwise 45-90 degrees. For push-pull: pull straight out firmly. If the mechanism is stuck, the internal latch may be damaged — replace the entire head assembly.

Machine doesn't stop when e-stop is pressed

Critical safety issue. Immediately lock out the machine. Check wiring — NC contacts must be in series with the safety relay. Verify the safety relay is functioning. A broken wire in an NC circuit should cause a stop, so check for a wiring bypass.

Safety relay faults after e-stop reset

The safety relay detects a cross-fault between the two monitoring channels. Check that both NC contacts on the e-stop are switching simultaneously. One contact may be welded closed — replace the contact block.

주요 사양

Actuator Function
Twist-to-release
Actuator Type
Mushroom 40mm
ATEX Zone
Zone 1, Zone 21
Certifications
ATEX, IECEx, CE
Color
Red

사용자 후기

+

“XB4-BS8445 meets EN/ISO 13850 requirements. Always wire NC contacts through a safety relay, never direct to contactor. Test monthly.”

Reddit r/PLC 26 추천 스레드 보기 →

데이터 출처

사양 및 제품 데이터는 다음 참고 자료에서 수집되었습니다.

XB4BS8445 Product Page

https://www.se.com/ww/en/product/XB4BS8445/

접속일 April 04, 2026