Schneider Electric · Harmony XB4 ATEX Dòng sản phẩm

XB4-BS8445

Hoạt động
ATEX IECEX CE

ATEX Emergency Stop Twist Release

Mã sản phẩm: B - S - 844
Schneider Electric Harmony XB4 ATEX Dòng sản phẩm Introduced circa 2008
Schneider Electric XB4-BS8445 — ATEX Emergency Stop Twist Release

ATEX-certified 40mm mushroom emergency stop for hazardous areas.

Ứng Dụng Phổ Biến

Critical safety device on oil drilling platforms, gas compressor stations, and chemical reactors. ATEX Zone 1 certification ensures the e-stop itself cannot become an ignition source. Twist-to-release prevents accidental restart in hazardous environments.

Thông số kỹ thuật

Actuator Function
Twist-to-release
Actuator Type
Mushroom 40mm
ATEX Zone
Zone 1, Zone 21
Certifications
ATEX, IECEx, CE
Color
Red
Contact Configuration
1NC
Cutout Diameter
22mm
Explosion Group
IIC
IP Rating
IP66
Temperature Class
T6

Thông số kỹ thuật có biểu tượng này được liên kết đến trang nguồn gốc của nhà sản xuất

Bạn Cũng Cần

Đây là một thành phần mô-đun. Để lắp ráp hoàn chỉnh, bạn có thể cần thêm:

Các Lựa Chọn Tương Thích

Các sản phẩm này là các tham chiếu chéo tương đương về chức năng từ các nhà sản xuất khác.

Hướng Dẫn Cài Đặt Nhanh

Panel cutout: 22mm. Mount with the yellow backing plate visible (required by EN/ISO 13850).

Wiring: Wire NC contacts in series with the safety relay input channels. Use dual-channel wiring for SIL 3 / PLe applications. Never wire directly to a motor contactor.

Testing: Press the e-stop and verify the machine stops within the required time. Test the reset mechanism. Repeat monthly per EN/ISO 13850.

Kích thước

Front 22mm cutout 40mm head Side panel terminals

Sơ đồ đấu dây

L T 21 22 NC (closed) opens on press

Khắc phục sự cố

E-stop won't reset (twist/pull doesn't release)

Check for debris in the mechanism. For twist-release: turn clockwise 45-90 degrees. For push-pull: pull straight out firmly. If the mechanism is stuck, the internal latch may be damaged — replace the entire head assembly.

Machine doesn't stop when e-stop is pressed

Critical safety issue. Immediately lock out the machine. Check wiring — NC contacts must be in series with the safety relay. Verify the safety relay is functioning. A broken wire in an NC circuit should cause a stop, so check for a wiring bypass.

Safety relay faults after e-stop reset

The safety relay detects a cross-fault between the two monitoring channels. Check that both NC contacts on the e-stop are switching simultaneously. One contact may be welded closed — replace the contact block.

Thông số kỹ thuật nhanh

Actuator Function
Twist-to-release
Actuator Type
Mushroom 40mm
ATEX Zone
Zone 1, Zone 21
Certifications
ATEX, IECEx, CE
Color
Red

Những Đánh Giá Từ Khách Hàng

+

“XB4-BS8445 meets EN/ISO 13850 requirements. Always wire NC contacts through a safety relay, never direct to contactor. Test monthly.”

Reddit r/PLC 26 lượt bình chọn Xem ren

Nguồn Dữ Liệu

Thông số kỹ thuật và dữ liệu sản phẩm được trích dẫn từ các tài liệu tham khảo sau.

XB4BS8445 Product Page

https://www.se.com/ww/en/product/XB4BS8445/

Truy cập ngày April 04, 2026

Nguồn