Schneider Electric · Harmony XB4 ATEX Řada

XB4-BS8445

Aktivní
ATEX IECEX CE

ATEX Emergency Stop Twist Release

Katalogové číslo: B - S - 844
Schneider Electric Harmony XB4 ATEX Řada Introduced circa 2008
Schneider Electric XB4-BS8445 — ATEX Emergency Stop Twist Release

ATEX-certified 40mm mushroom emergency stop for hazardous areas.

Běžné aplikace

Critical safety device on oil drilling platforms, gas compressor stations, and chemical reactors. ATEX Zone 1 certification ensures the e-stop itself cannot become an ignition source. Twist-to-release prevents accidental restart in hazardous environments.

Specifikace

Actuator Function
Twist-to-release
Actuator Type
Mushroom 40mm
ATEX Zone
Zone 1, Zone 21
Certifications
ATEX, IECEx, CE
Color
Red
Contact Configuration
1NC
Cutout Diameter
22mm
Explosion Group
IIC
IP Rating
IP66
Temperature Class
T6

Specifikace s touto ikonou odkazují na původní stránku výrobce

Budete také potřebovat

Toto je modulární komponenta. Pro kompletní sestavu budete možná potřebovat také:

Kompatibilní alternativy

Tyto produkty jsou funkčně ekvivalentní křížové reference od jiných výrobců.

Stručný průvodce instalací

Panel cutout: 22mm. Mount with the yellow backing plate visible (required by EN/ISO 13850).

Wiring: Wire NC contacts in series with the safety relay input channels. Use dual-channel wiring for SIL 3 / PLe applications. Never wire directly to a motor contactor.

Testing: Press the e-stop and verify the machine stops within the required time. Test the reset mechanism. Repeat monthly per EN/ISO 13850.

Rozměry

Front 22mm cutout 40mm head Side panel terminals

Schéma zapojení

L T 21 22 NC (closed) opens on press

Řešení problémů

E-stop won't reset (twist/pull doesn't release)

Check for debris in the mechanism. For twist-release: turn clockwise 45-90 degrees. For push-pull: pull straight out firmly. If the mechanism is stuck, the internal latch may be damaged — replace the entire head assembly.

Machine doesn't stop when e-stop is pressed

Critical safety issue. Immediately lock out the machine. Check wiring — NC contacts must be in series with the safety relay. Verify the safety relay is functioning. A broken wire in an NC circuit should cause a stop, so check for a wiring bypass.

Safety relay faults after e-stop reset

The safety relay detects a cross-fault between the two monitoring channels. Check that both NC contacts on the e-stop are switching simultaneously. One contact may be welded closed — replace the contact block.

Stručné specifikace

Actuator Function
Twist-to-release
Actuator Type
Mushroom 40mm
ATEX Zone
Zone 1, Zone 21
Certifications
ATEX, IECEx, CE
Color
Red

Co říkají uživatelé

+

“XB4-BS8445 meets EN/ISO 13850 requirements. Always wire NC contacts through a safety relay, never direct to contactor. Test monthly.”

Reddit r/PLC 26 hlasů Zobrazit vlákno →