Eaton · M22 ATEX Dòng sản phẩm

M22-PVL

Hoạt động
ATEX IECEX CE UL

ATEX Emergency Stop 38mm Push-Pull

Mã sản phẩm: M22
Eaton M22 ATEX Dòng sản phẩm Introduced circa 2010
Eaton M22-PVL — ATEX Emergency Stop 38mm Push-Pull

Eaton M22 ATEX-certified emergency stop with push-pull reset.

Ứng Dụng Phổ Biến

Used on ATEX-certified motor control panels in petrochemical plants and grain handling facilities. Push-pull reset is preferred for cold storage and gloved operations in hazardous atmospheres.

Thông số kỹ thuật

Actuator Function
Push-pull
Actuator Type
Mushroom 38mm
ATEX Zone
Zone 1, Zone 21
Certifications
ATEX, IECEx, CE, UL
Color
Red
Contact Configuration
1NC
Cutout Diameter
22.5mm
Explosion Group
IIC
IP Rating
IP67
Temperature Class
T6

Thông số kỹ thuật có biểu tượng này được liên kết đến trang nguồn gốc của nhà sản xuất

Các Lựa Chọn Tương Thích

Các sản phẩm này là các tham chiếu chéo tương đương về chức năng từ các nhà sản xuất khác.

Hướng Dẫn Cài Đặt Nhanh

Panel cutout: 22.5mm. Mount with the yellow backing plate visible (required by EN/ISO 13850).

Wiring: Wire NC contacts in series with the safety relay input channels. Use dual-channel wiring for SIL 3 / PLe applications. Never wire directly to a motor contactor.

Testing: Press the e-stop and verify the machine stops within the required time. Test the reset mechanism. Repeat monthly per EN/ISO 13850.

Kích thước

Front 22.5mm cutout 40mm head Side panel terminals

Sơ đồ đấu dây

L T 21 22 NC (closed) opens on press

Khắc phục sự cố

E-stop won't reset (twist/pull doesn't release)

Check for debris in the mechanism. For twist-release: turn clockwise 45-90 degrees. For push-pull: pull straight out firmly. If the mechanism is stuck, the internal latch may be damaged — replace the entire head assembly.

Machine doesn't stop when e-stop is pressed

Critical safety issue. Immediately lock out the machine. Check wiring — NC contacts must be in series with the safety relay. Verify the safety relay is functioning. A broken wire in an NC circuit should cause a stop, so check for a wiring bypass.

Safety relay faults after e-stop reset

The safety relay detects a cross-fault between the two monitoring channels. Check that both NC contacts on the e-stop are switching simultaneously. One contact may be welded closed — replace the contact block.

Thông số kỹ thuật nhanh

Actuator Function
Push-pull
Actuator Type
Mushroom 38mm
ATEX Zone
Zone 1, Zone 21
Certifications
ATEX, IECEx, CE, UL
Color
Red

Những Đánh Giá Từ Khách Hàng

+

“M22-PVL meets EN/ISO 13850 requirements. Always wire NC contacts through a safety relay, never direct to contactor. Test monthly.”

Reddit r/PLC 19 lượt bình chọn Xem ren