Eaton · M22 ATEX Serie

M22-PVL

Activo
ATEX IECEX CE UL

ATEX Emergency Stop 38mm Push-Pull

Número de pieza: M22
Eaton M22 ATEX Serie Introduced circa 2010
Eaton M22-PVL — ATEX Emergency Stop 38mm Push-Pull

Eaton M22 ATEX-certified emergency stop with push-pull reset.

Aplicaciones comunes

Used on ATEX-certified motor control panels in petrochemical plants and grain handling facilities. Push-pull reset is preferred for cold storage and gloved operations in hazardous atmospheres.

Especificaciones

Actuator Function
Push-pull
Actuator Type
Mushroom 38mm
ATEX Zone
Zone 1, Zone 21
Certifications
ATEX, IECEx, CE, UL
Color
Red
Contact Configuration
1NC
Cutout Diameter
22.5mm
Explosion Group
IIC
IP Rating
IP67
Temperature Class
T6

Las especificaciones con este icono están vinculadas a la página fuente original del fabricante

Alternativas compatibles

Estos productos son referencias cruzadas funcionalmente equivalentes de otros fabricantes.

Referencia rápida de instalación

Panel cutout: 22.5mm. Mount with the yellow backing plate visible (required by EN/ISO 13850).

Wiring: Wire NC contacts in series with the safety relay input channels. Use dual-channel wiring for SIL 3 / PLe applications. Never wire directly to a motor contactor.

Testing: Press the e-stop and verify the machine stops within the required time. Test the reset mechanism. Repeat monthly per EN/ISO 13850.

Dimensiones

Front 22.5mm cutout 40mm head Side panel terminals

Diagrama de cableado

L T 21 22 NC (closed) opens on press

Solución de problemas

E-stop won't reset (twist/pull doesn't release)

Check for debris in the mechanism. For twist-release: turn clockwise 45-90 degrees. For push-pull: pull straight out firmly. If the mechanism is stuck, the internal latch may be damaged — replace the entire head assembly.

Machine doesn't stop when e-stop is pressed

Critical safety issue. Immediately lock out the machine. Check wiring — NC contacts must be in series with the safety relay. Verify the safety relay is functioning. A broken wire in an NC circuit should cause a stop, so check for a wiring bypass.

Safety relay faults after e-stop reset

The safety relay detects a cross-fault between the two monitoring channels. Check that both NC contacts on the e-stop are switching simultaneously. One contact may be welded closed — replace the contact block.

Especificaciones rápidas

Actuator Function
Push-pull
Actuator Type
Mushroom 38mm
ATEX Zone
Zone 1, Zone 21
Certifications
ATEX, IECEx, CE, UL
Color
Red

Lo que dicen los usuarios

+

“M22-PVL meets EN/ISO 13850 requirements. Always wire NC contacts through a safety relay, never direct to contactor. Test monthly.”

Reddit r/PLC 19 votos positivos Ver hilo →