Schneider Electric · Harmony XB4 Série

XB4-BVB4-230

Ativo
UL CSA CE

Schneider XB4BVB4 Red Pilot Light 24V AC/DC (Harmony XB4)

Número de peça: B - V
Schneider Electric Harmony XB4 Série Introduced circa 2003

Schneider XB4 red pilot light for 230V AC.

Aplicações comuns

Red 230V indicator for European direct-mains panels. Fault indication on 230V circuits.

Especificações

Certifications
UL, CSA, CE
Color
Red
Cutout Diameter
22mm
Device type
Harmony XB4 complete pilot/indicator light (status, NOT a pushbutton)
IP Rating
IP66 / IP69K
LED Voltage
24V AC/DC
Material
Metal
Pn note
Corrected: XB4BVB4 = red, 24V AC/DC (se.com). Was mislabeled 230V (bogus -230 suffix). XB4-BV voltage letter B=24V (G=110-120V, M=230-240V). AUDIT other XB4-BV*-230 entries.
Pn status
voltage-corrected

Referência rápida de instalação

Panel cutout: 22mm. Insert from the front, secure with mounting nut.

LED module: Check the voltage rating matches your supply (typically 24V DC or 230V AC). Connect to PLC digital output or relay contact for status indication.

Color meaning (IEC 60204-1): Green = normal/running. Red = fault/danger. Yellow = warning/caution. Blue = mandatory action. White = neutral/general.

Dimensões

Front 22mm cutout panel hole diameter Side panel contact ~45mm depth

Solução de problemas

Light is dim or flickering

Check supply voltage matches the LED module rating. Low voltage causes dimming. If voltage is correct, the LED module is failing — replace it. LED modules have finite life (typically 50K-100K hours).

Light doesn't turn on

Verify voltage at the terminals with a multimeter. Check the PLC output or relay driving the light. LED modules are polarity-sensitive on DC circuits — try reversing the leads.

Onde comprar

Faixa de preço

$11.17 — $147.07

em 2 distribuidores

Especificações rápidas

Certifications
UL, CSA, CE
Color
Red
Cutout Diameter
22mm
Device type
Harmony XB4 complete pilot/indicator light (status, NOT a pushbutton)
IP Rating
IP66 / IP69K

O que os usuários dizem

+

“Red 230V indicator for European direct-mains panels. Fault indication on 230V circuits.”