XALD321
AtivoSchneider Harmony XALD 3-Button Station (green/red/green, XALD321)
Schneider XALD 3-button station — start, stop, and e-stop.
Aplicações comuns
Complete motor control station: green start, red stop, and red mushroom e-stop in one IP66 enclosure. The standard for remote motor control on conveyors, pumps, and fans. Meets OSHA requirements for accessible e-stop within reach of the operator.
Especificações
|
Certifications
Third-party safety certifications. UL = required for US NEC installations. CE = EU compliance. CSA = Canadian standards.
|
UL, CSA, CE
|
|
Color
Button/actuator color. Green = start/go, Red = stop/emergency, Yellow = caution, Blue = reset (per IEC 60204-1).
|
Green + Red + Green (three flush pushbuttons)
|
|
Contact Configuration
Normally Open — circuit is off until you press. Standard for start/go/enable functions.
|
~2NO + 1NC (verify from full catalog number)
|
|
Full catalog
|
XALD321H29H7
|
|
IP Rating
IP66: Dust-tight and withstands powerful water jets from any direction. Standard for outdoor and washdown applications.
|
IP66
|
|
Mounting Type
How the button attaches to the panel. Panel mount is standard — installs through a cutout from the front.
|
Surface mount (enclosed)
|
|
Operators
|
Green flush / red flush / green flush Ø22 (XB5) — NO e-stop mushroom
|
|
Pn note
|
Corrected: XALD321 = green/red/green 3-button station (se.com datasheet), NOT Start/Stop/E-Stop. The 3rd button is green flush, not an e-stop mushroom.
|
|
Pn status
|
mislabel-corrected
|
Referência rápida de instalação
Panel cutout: 22mm. Insert from the front of the panel, secure with mounting nut from behind (tighten to 2-3 Nm).
Contact block: Snap or screw the contact block onto the rear of the button body. Ensure the contact block orientation matches the wiring diagram — NO terminals are usually marked.
Wiring: Use 0.5-2.5mm² stranded wire with ferrules. Tighten screw terminals to 0.8 Nm. Test the button function before energizing the circuit.
Dimensões
Diagrama de fiação
Solução de problemas
Button doesn't respond when pressed
Check the contact block first — it's the most common failure point. Test continuity across the NO or NC terminals with a multimeter. If no click is felt, the return spring in the head may be broken.
Works intermittently
Contact block contacts are pitted or burned. Replace the contact block — don't try to file the contacts. Check if the rated cycle count has been exceeded.
Button feels mushy or doesn't click
The spring return mechanism in the button head is worn. Replace the head. The contact block can usually be reused if it tests OK.
Onde comprar
Faixa de preço
$5.37 — $45.32
em 2 distribuidores
Especificações rápidas
- Certifications
- UL, CSA, CE
- Color
- Green + Red + Green (three flush pushbuttons)
- Contact Configuration
- ~2NO + 1NC (verify from full catalog number)
- Full catalog
- XALD321H29H7
- IP Rating
- IP66
O que os usuários dizem
“Complete motor control station: green start, red stop, and red mushroom e-stop in one IP66 enclosure. The standard for remote motor control on conveyors, pumps, and fans. Meets OSHA requirements for a”
Saiba mais
Graus de proteção IP explicados
O que IP65, IP66, IP67, IP69K significam para sua aplicação
Guia 22mm vs. 30mm
Qual tamanho de recorte de painel você precisa?
Blocos de contato: NO vs. NC
Como escolher e conectar blocos de contato
Ferramenta localizador de botões
Encontre o botão certo por tipo, tamanho e cor