XALD321
AttivoHarmony XALD 3-Button Start/Stop/E-Stop Station
Schneider XALD 3-button station — start, stop, and e-stop.
Applicazioni Comuni
Complete motor control station: green start, red stop, and red mushroom e-stop in one IP66 enclosure. The standard for remote motor control on conveyors, pumps, and fans. Meets OSHA requirements for accessible e-stop within reach of the operator.
Specifiche
|
Certifications
Third-party safety certifications. UL = required for US NEC installations. CE = EU compliance. CSA = Canadian standards.
|
UL, CSA, CE
|
|
Color
Button/actuator color. Green = start/go, Red = stop/emergency, Yellow = caution, Blue = reset (per IEC 60204-1).
|
Green + Red + E-Stop
|
|
Contact Configuration
1NO + 1NC: One circuit closes and one opens when pressed. Common for start buttons that also signal 'running' state.
|
2x 1NO + 1NC (e-stop)
|
|
IP Rating
IP66: Dust-tight and withstands powerful water jets from any direction. Standard for outdoor and washdown applications.
|
IP66
|
|
Mounting Type
How the button attaches to the panel. Panel mount is standard — installs through a cutout from the front.
|
Surface mount (enclosed)
|
Guida Rapida all'Installazione
Panel cutout: 22mm. Insert from the front of the panel, secure with mounting nut from behind (tighten to 2-3 Nm).
Contact block: Snap or screw the contact block onto the rear of the button body. Ensure the contact block orientation matches the wiring diagram — NO terminals are usually marked.
Wiring: Use 0.5-2.5mm² stranded wire with ferrules. Tighten screw terminals to 0.8 Nm. Test the button function before energizing the circuit.
Dimensioni
Schema di Cablaggio
Risoluzione dei Problemi
Button doesn't respond when pressed
Check the contact block first — it's the most common failure point. Test continuity across the NO or NC terminals with a multimeter. If no click is felt, the return spring in the head may be broken.
Works intermittently
Contact block contacts are pitted or burned. Replace the contact block — don't try to file the contacts. Check if the rated cycle count has been exceeded.
Button feels mushy or doesn't click
The spring return mechanism in the button head is worn. Replace the head. The contact block can usually be reused if it tests OK.
Dove Acquistare
Fascia di prezzo
$5.37 — $45.32
presso 2 distributori
Specifiche Rapide
- Certifications
- UL, CSA, CE
- Color
- Green + Red + E-Stop
- Contact Configuration
- 2x 1NO + 1NC (e-stop)
- IP Rating
- IP66
- Mounting Type
- Surface mount (enclosed)
Cosa Dicono gli Utenti
“Complete motor control station: green start, red stop, and red mushroom e-stop in one IP66 enclosure. The standard for remote motor control on conveyors, pumps, and fans. Meets OSHA requirements for a”
Approfondisci
Classificazioni IP Spiegate
Cosa significano IP65, IP66, IP67, IP69K per la Sua applicazione
Guida 22mm vs 30mm
Quale dimensione del foro pannello Le serve?
Blocchi Contatti: NO vs NC
Come scegliere e cablare i blocchi contatti
Strumento Trova Pulsante
Trovi il pulsante giusto per tipo, dimensione e colore