Schneider Electric · Harmony XALD Seeria

XALD321

Aktiivne
UL CSA CE

Harmony XALD 3-Button Start/Stop/E-Stop Station

Schneider Electric Harmony XALD Seeria Introduced circa 2003

Schneider XALD 3-button station — start, stop, and e-stop.

Tüüpilised rakendused

Complete motor control station: green start, red stop, and red mushroom e-stop in one IP66 enclosure. The standard for remote motor control on conveyors, pumps, and fans. Meets OSHA requirements for accessible e-stop within reach of the operator.

Spetsifikatsioonid

Certifications
UL, CSA, CE
Color
Green + Red + E-Stop
Contact Configuration
2x 1NO + 1NC (e-stop)
IP Rating
IP66
Mounting Type
Surface mount (enclosed)

Paigalduse kiirjuhend

Panel cutout: 22mm. Insert from the front of the panel, secure with mounting nut from behind (tighten to 2-3 Nm).

Contact block: Snap or screw the contact block onto the rear of the button body. Ensure the contact block orientation matches the wiring diagram — NO terminals are usually marked.

Wiring: Use 0.5-2.5mm² stranded wire with ferrules. Tighten screw terminals to 0.8 Nm. Test the button function before energizing the circuit.

Mõõtmed

Ühenduseskeem

11 12 NO 21 22 NC

Veaotsing

Button doesn't respond when pressed

Check the contact block first — it's the most common failure point. Test continuity across the NO or NC terminals with a multimeter. If no click is felt, the return spring in the head may be broken.

Works intermittently

Contact block contacts are pitted or burned. Replace the contact block — don't try to file the contacts. Check if the rated cycle count has been exceeded.

Button feels mushy or doesn't click

The spring return mechanism in the button head is worn. Replace the head. The contact block can usually be reused if it tests OK.

Kust osta

Hinnavahemik

$5.37 — $45.32

2 edasimüüja juures

Kiirspetsifikatsioonid

Certifications
UL, CSA, CE
Color
Green + Red + E-Stop
Contact Configuration
2x 1NO + 1NC (e-stop)
IP Rating
IP66
Mounting Type
Surface mount (enclosed)

Mida kasutajad ütlevad

+

“Complete motor control station: green start, red stop, and red mushroom e-stop in one IP66 enclosure. The standard for remote motor control on conveyors, pumps, and fans. Meets OSHA requirements for a”

Reddit r/PLC 12 poolthääli Vaata arutelu →