Eaton · M22 Seria

M22-D-G

Aktywny
UL CSA CE ATEX

M22 Green Flush Push Button

Numer katalogowy: M22 - D - G
Eaton M22 Seria Introduced circa 2000
Eaton M22-D-G — M22 Green Flush Push Button

Green flush momentary push button for Eaton M22 series. 22.5mm cutout, IP67 front. Complete unit with 1NO contact.

Typowe Zastosowania

Eaton equivalent of the Schneider ZB4-BA3. Found on European-built machinery, food processing equipment, and packaging lines. The M22 series is popular in the automotive manufacturing sector — many German, Austrian, and Czech machine builders spec Eaton by default. IP67 front face with IP69K option handles high-pressure washdown in food and beverage plants. The modular RMQ-Titan system means you can mix and match heads, contact blocks, and LED modules from the same M22 family.

Specyfikacje

Actuator Function
Momentary
Actuator Shape
Round
Actuator Type
Flush
Bezel
Silver
Certifications
UL, CSA, CE, ATEX
Color
Green
Contact Configuration
1NO
Cutout Diameter
22.5mm
Environmental Rating
IP67, IP69K, NEMA 4X, NEMA 13
Illumination
Non-illuminated
IP Rating
IP67 (front)
Material
Plastic/Metal bezel
Mechanical Life
5,000,000 cycles
Mounting Type
Panel
Operating Cycles
5 million
Max Operating Temp
70°C
Min Operating Temp
-25°C
Series
M22

Specyfikacje z tą ikoną są powiązane z oryginalną stroną źródłową producenta

Będziesz Potrzebować Również

To jest komponent modułowy. Do kompletnego zestawu mogą być potrzebne również:

Skrócona Instrukcja Montażu

Panel cutout: 22.5mm. Insert from the front of the panel, secure with mounting nut from behind (tighten to 2-3 Nm).

Contact block: Snap or screw the contact block onto the rear of the button body. Ensure the contact block orientation matches the wiring diagram — NO terminals are usually marked.

Wiring: Use 0.5-2.5mm² stranded wire with ferrules. Tighten screw terminals to 0.8 Nm. Test the button function before energizing the circuit.

Wymiary

Front 22.5mm cutout panel hole diameter Side panel contact ~45mm depth

Schemat Połączeń

L T 11 12 NO (open) press ↓

Rozwiązywanie Problemów

Button doesn't respond when pressed

Check the contact block first — it's the most common failure point. Test continuity across the NO or NC terminals with a multimeter. If no click is felt, the return spring in the head may be broken.

Works intermittently

Contact block contacts are pitted or burned. Replace the contact block — don't try to file the contacts. Check if the rated cycle count has been exceeded.

Button feels mushy or doesn't click

The spring return mechanism in the button head is worn. Replace the head. The contact block can usually be reused if it tests OK.

Skrócone Specyfikacje

Actuator Function
Momentary
Actuator Shape
Round
Actuator Type
Flush
Bezel
Silver
Certifications
UL, CSA, CE, ATEX

Co Mówią Użytkownicy

“We're redoing all our control panels and need to pick one brand. The Eaton M22 IP67 rating is slightly better than ABB's IP65, but ABB's modular contact blocks snap on faster during assembly. Price is nearly identical from our distributor.”

Reddit r/PLC by panel_builder_mike 34 głosy za Zobacz wątek →
+

“We standardized on Eaton M22 across all our plants. The modular system means we keep fewer spares — one contact block fits everything. Silver bezel looks professional too.”

Reddit r/PLC by controls_engineer_42 24 głosy za Zobacz wątek →