Pepperl+Fuchs · GDL Seria

GDL31-GP

Aktywny
ATEX IECEX

ATEX Green Push Button GRP Enclosure

Pepperl+Fuchs GDL Seria Introduced circa 2005
Pepperl+Fuchs GDL31-GP — ATEX Green Push Button GRP Enclosure

Pepperl+Fuchs ATEX-certified green push button in GRP (fiberglass) enclosure for Zone 1.

Typowe Zastosowania

Purpose-built for hazardous area installations where the entire button assembly must be explosion-proof. The GRP (glass-reinforced polyester) enclosure is corrosion-resistant and lighter than cast aluminum — preferred on offshore oil platforms where weight and salt spray are concerns.

Specyfikacje

ATEX Zone
Zone 1, Zone 2
Certifications
ATEX, IECEx
Color
Green
Contact Configuration
1NO
Cutout Diameter
22mm
Explosion Group
IIC
IP Rating
IP66
Material
GRP (fiberglass)
Temperature Class
T6

Specyfikacje z tą ikoną są powiązane z oryginalną stroną źródłową producenta

Kompatybilne Alternatywy

Te produkty to funkcjonalnie równoważne odnośniki krzyżowe od innych producentów.

Skrócona Instrukcja Montażu

Panel cutout: 22mm. Insert from the front of the panel, secure with mounting nut from behind (tighten to 2-3 Nm).

Contact block: Snap or screw the contact block onto the rear of the button body. Ensure the contact block orientation matches the wiring diagram — NO terminals are usually marked.

Wiring: Use 0.5-2.5mm² stranded wire with ferrules. Tighten screw terminals to 0.8 Nm. Test the button function before energizing the circuit.

Wymiary

Front 22mm cutout panel hole diameter Side panel contact ~45mm depth

Schemat Połączeń

L T 11 12 NO (open) press ↓

Rozwiązywanie Problemów

Button doesn't respond when pressed

Check the contact block first — it's the most common failure point. Test continuity across the NO or NC terminals with a multimeter. If no click is felt, the return spring in the head may be broken.

Works intermittently

Contact block contacts are pitted or burned. Replace the contact block — don't try to file the contacts. Check if the rated cycle count has been exceeded.

Button feels mushy or doesn't click

The spring return mechanism in the button head is worn. Replace the head. The contact block can usually be reused if it tests OK.

Gdzie Kupić

Przedział cenowy

$9.97 — $57.87

u 3 dystrybutorów

Skrócone Specyfikacje

ATEX Zone
Zone 1, Zone 2
Certifications
ATEX, IECEx
Color
Green
Contact Configuration
1NO
Cutout Diameter
22mm

Co Mówią Użytkownicy

+

“Make sure you get Zone 1 rated, not just Zone 2. The Schneider XB4 ATEX range is solid but the Pepperl+Fuchs units with GRP enclosures are better for offshore where salt spray is a factor.”

PLCTalk 15 głosy za Zobacz wątek →

Źródła Danych

Specyfikacje i dane produktowe pochodzą z poniższych źródeł.

GDL31-GP Product Page

https://www.pepperl-fuchs.com/global/en/search.htm?q=GDL31

Data dostępu: April 04, 2026

Źródło