Pepperl+Fuchs GDL31-GP — ATEX Green Push Button GRP Enclosure

Pepperl+Fuchs ATEX-certified green push button in GRP (fiberglass) enclosure for Zone 1.

Aplikasi Umum

Purpose-built for hazardous area installations where the entire button assembly must be explosion-proof. The GRP (glass-reinforced polyester) enclosure is corrosion-resistant and lighter than cast aluminum — preferred on offshore oil platforms where weight and salt spray are concerns.

Spesifikasi

ATEX Zone
Zone 1, Zone 2
Certifications
ATEX, IECEx
Color
Green
Contact Configuration
1NO
Cutout Diameter
22mm
Explosion Group
IIC
IP Rating
IP66
Material
GRP (fiberglass)
Temperature Class
T6

Spesifikasi dengan ikon ini terhubung ke halaman sumber asli pabrikan

Alternatif yang Kompatibel

Produk-produk ini merupakan referensi silang yang setara secara fungsional dari produsen lain.

Referensi Cepat Instalasi

Panel cutout: 22mm. Insert from the front of the panel, secure with mounting nut from behind (tighten to 2-3 Nm).

Contact block: Snap or screw the contact block onto the rear of the button body. Ensure the contact block orientation matches the wiring diagram — NO terminals are usually marked.

Wiring: Use 0.5-2.5mm² stranded wire with ferrules. Tighten screw terminals to 0.8 Nm. Test the button function before energizing the circuit.

Dimensi

Front 22mm cutout panel hole diameter Side panel contact ~45mm depth

Diagram Pengkabelan

L T 11 12 NO (open) press ↓

Pemecahan Masalah

Button doesn't respond when pressed

Check the contact block first — it's the most common failure point. Test continuity across the NO or NC terminals with a multimeter. If no click is felt, the return spring in the head may be broken.

Works intermittently

Contact block contacts are pitted or burned. Replace the contact block — don't try to file the contacts. Check if the rated cycle count has been exceeded.

Button feels mushy or doesn't click

The spring return mechanism in the button head is worn. Replace the head. The contact block can usually be reused if it tests OK.

Spesifikasi Cepat

ATEX Zone
Zone 1, Zone 2
Certifications
ATEX, IECEx
Color
Green
Contact Configuration
1NO
Cutout Diameter
22mm

Apa Kata Mereka

+

“Make sure you get Zone 1 rated, not just Zone 2. The Schneider XB4 ATEX range is solid but the Pepperl+Fuchs units with GRP enclosures are better for offshore where salt spray is a factor.”

PLCTalk 15 suka Lihat ulir →

Sumber Data

Spesifikasi dan data produk bersumber dari referensi berikut.

GDL31-GP Product Page

https://www.pepperl-fuchs.com/global/en/search.htm?q=GDL31

Diakses April 04, 2026

Sumber