Pepperl+Fuchs · GDL Baureihe

GDL31-GP

Aktiv
ATEX IECEX

ATEX Green Push Button GRP Enclosure

Pepperl+Fuchs GDL Baureihe Introduced circa 2005
Pepperl+Fuchs GDL31-GP — ATEX Green Push Button GRP Enclosure

Pepperl+Fuchs ATEX-certified green push button in GRP (fiberglass) enclosure for Zone 1.

Typische Anwendungen

Purpose-built for hazardous area installations where the entire button assembly must be explosion-proof. The GRP (glass-reinforced polyester) enclosure is corrosion-resistant and lighter than cast aluminum — preferred on offshore oil platforms where weight and salt spray are concerns.

Spezifikationen

ATEX Zone
Zone 1, Zone 2
Certifications
ATEX, IECEx
Color
Green
Contact Configuration
1NO
Cutout Diameter
22mm
Explosion Group
IIC
IP Rating
IP66
Material
GRP (fiberglass)
Temperature Class
T6

Spezifikationen mit diesem Symbol sind mit der Original-Herstellerseite verlinkt

Kompatible Alternativen

Diese Produkte sind funktional gleichwertige Querverweise anderer Hersteller.

Installationskurzanleitung

Panel cutout: 22mm. Insert from the front of the panel, secure with mounting nut from behind (tighten to 2-3 Nm).

Contact block: Snap or screw the contact block onto the rear of the button body. Ensure the contact block orientation matches the wiring diagram — NO terminals are usually marked.

Wiring: Use 0.5-2.5mm² stranded wire with ferrules. Tighten screw terminals to 0.8 Nm. Test the button function before energizing the circuit.

Abmessungen

Front 22mm cutout panel hole diameter Side panel contact ~45mm depth

Schaltplan

L T 11 12 NO (open) press ↓

Fehlerbehebung

Button doesn't respond when pressed

Check the contact block first — it's the most common failure point. Test continuity across the NO or NC terminals with a multimeter. If no click is felt, the return spring in the head may be broken.

Works intermittently

Contact block contacts are pitted or burned. Replace the contact block — don't try to file the contacts. Check if the rated cycle count has been exceeded.

Button feels mushy or doesn't click

The spring return mechanism in the button head is worn. Replace the head. The contact block can usually be reused if it tests OK.

Kurzspezifikationen

ATEX Zone
Zone 1, Zone 2
Certifications
ATEX, IECEx
Color
Green
Contact Configuration
1NO
Cutout Diameter
22mm

Das sagen Anwender

+

“Make sure you get Zone 1 rated, not just Zone 2. The Schneider XB4 ATEX range is solid but the Pepperl+Fuchs units with GRP enclosures are better for offshore where salt spray is a factor.”

PLCTalk 15 Bewertungen Thread anzeigen →

Datenquellen

Spezifikationen und Produktdaten stammen aus folgenden Quellen.

GDL31-GP Product Page

https://www.pepperl-fuchs.com/global/en/search.htm?q=GDL31

Abgerufen am April 04, 2026