Eaton · M22 Série

M22-D-Y

Actif
UL CSA CE ATEX

M22 Yellow Flush Push Button

Référence : M22 - D - Y
Eaton M22 Série Introduced circa 2000
Eaton M22-D-Y — M22 Yellow Flush Push Button

Yellow flush momentary push button for Eaton M22 series. 22.5mm cutout, IP67 front. Complete unit with 1NO contact.

Applications courantes

Yellow push button used for abnormal or intervention functions per IEC 60204-1 — yellow signals caution or an action to suppress an abnormal condition. Common on conveyor systems for jam-clear functions, packaging lines for fault reset, and process control panels for alarm acknowledgement. In many panel designs, the yellow button sits between the green start and red stop as the operator's go-to for clearing faults without a full restart. The M22 series IP67 front face handles washdown environments. Pairs with the M22-D-G (green start) and M22-D-R (red stop) for a complete three-button station.

Spécifications

Actuator Shape
Round
Actuator Type
Flush
Certifications
UL, CSA, CE, ATEX
Color
Yellow
Contact Configuration
1NO
Cutout Diameter
22.5mm
IP Rating
IP67 (front)
Material
Plastic/Metal bezel
Mechanical Life
5,000,000 cycles
Mounting Type
Panel
Max Operating Temp
70°C
Min Operating Temp
-25°C

Les spécifications avec cette icône sont liées à la page source originale du fabricant

Vous aurez également besoin de

Ceci est un composant modulaire. Pour un assemblage complet, vous pourriez également avoir besoin de :

Alternatives compatibles

Ces produits sont des correspondances fonctionnellement équivalentes d'autres fabricants.

Référence rapide d'installation

Panel cutout: 22.5mm. Insert from the front of the panel, secure with mounting nut from behind (tighten to 2-3 Nm).

Contact block: Snap or screw the contact block onto the rear of the button body. Ensure the contact block orientation matches the wiring diagram — NO terminals are usually marked.

Wiring: Use 0.5-2.5mm² stranded wire with ferrules. Tighten screw terminals to 0.8 Nm. Test the button function before energizing the circuit.

Dimensions

Front 22.5mm cutout panel hole diameter Side panel contact ~45mm depth

Schéma de câblage

L T 11 12 NO (open) press ↓

Dépannage

Button doesn't respond when pressed

Check the contact block first — it's the most common failure point. Test continuity across the NO or NC terminals with a multimeter. If no click is felt, the return spring in the head may be broken.

Works intermittently

Contact block contacts are pitted or burned. Replace the contact block — don't try to file the contacts. Check if the rated cycle count has been exceeded.

Button feels mushy or doesn't click

The spring return mechanism in the button head is worn. Replace the head. The contact block can usually be reused if it tests OK.

Spécifications rapides

Actuator Shape
Round
Actuator Type
Flush
Certifications
UL, CSA, CE, ATEX
Color
Yellow
Contact Configuration
1NO

Ce qu'en disent les utilisateurs

“Yellow means caution or intervention per IEC 60204-1. We use them for reset buttons after a fault, jog functions, and test/manual override. Never use yellow for start or stop — that confuses operators.”

Reddit r/PLC by standards_nerd 27 votes positifs Voir le fil →

Sources de données

Spécifications et données produit issues des références suivantes.

Eaton M22-D-Y Product Page

https://www.eaton.com/us/en-us/skuPage.M22-D-Y.html

Consulté le March 29, 2026

Source