Fuji Electric · AR22 Serie

AR22PR-122R

Activo
JIS UL CE

AR22 22mm Red Indicator 24V

Fuji Electric AR22 Serie Introduced circa 2000

Fuji AR22 red indicator.

Aplicaciones comunes

Fault indicator for Fuji panels.

Especificaciones

Certifications
JIS, UL, CE
Color
Red
Cutout Diameter
22mm
LED Voltage
24V DC

Referencia rápida de instalación

Panel cutout: 22mm. Insert from the front, secure with mounting nut.

LED module: Check the voltage rating matches your supply (typically 24V DC or 230V AC). Connect to PLC digital output or relay contact for status indication.

Color meaning (IEC 60204-1): Green = normal/running. Red = fault/danger. Yellow = warning/caution. Blue = mandatory action. White = neutral/general.

Dimensiones

Front 22mm cutout panel hole diameter Side panel contact ~45mm depth

Solución de problemas

Light is dim or flickering

Check supply voltage matches the LED module rating. Low voltage causes dimming. If voltage is correct, the LED module is failing — replace it. LED modules have finite life (typically 50K-100K hours).

Light doesn't turn on

Verify voltage at the terminals with a multimeter. Check the PLC output or relay driving the light. LED modules are polarity-sensitive on DC circuits — try reversing the leads.

Dónde comprar

Rango de precios

$1.49 — $17.48

en 2 distribuidores

Especificaciones rápidas

Certifications
JIS, UL, CE
Color
Red
Cutout Diameter
22mm
LED Voltage
24V DC

Lo que dicen los usuarios

+

“Fault indicator for Fuji panels.”

Reddit r/PLC 9 votos positivos Ver hilo →