Eaton · M22 Series

M22-PV-K01

Active
UL CSA CE IEC 60947-5-5

M22 Red Mushroom Emergency Stop (Push-Pull)

Part number: M22 - PV - K01
Eaton M22 Series Introduced circa 2000
Eaton M22-PV-K01 — M22 Red Mushroom Emergency Stop (Push-Pull)

Red 38mm mushroom head emergency stop push button, push-pull reset, for Eaton M22 series. 22.5mm cutout, IP67.

Common Applications

Emergency stop with push-pull reset mechanism. The knob must be pulled out to reset — simpler than twist-release for operators wearing heavy gloves (common in cold storage, meat processing). Found on food processing lines, warehouse conveyor systems, and agricultural equipment. The maintained push-pull action provides clear visual indication: button extended = machine can run, button pushed in = machine stopped. Wire the NC contact in series with the safety relay.

Specifications

Actuator
Knob, push-pull
Actuator Function
Maintained
Actuator Type
Mushroom Head
Certifications
UL, CSA, CE, IEC 60947-5-5
Color
Red
Contact Configuration
1NC
Cutout Diameter
22.5mm
Environmental Rating
IP67, IP69K, NEMA 4X, NEMA 13
Head diameter
38mm
Illumination
Non-illuminated
IP Rating
IP67
Material
Plastic
Mounting Type
Panel
Reset type
Push-Pull
Series
M22
UPC
786685271743

Specs with this icon are linked to the manufacturer's original source page

You'll Also Need

This is a modular component. For a complete assembly, you may also need:

Installation Quick Reference

Panel cutout: 22.5mm. Mount with the yellow backing plate visible (required by EN/ISO 13850).

Wiring: Wire NC contacts in series with the safety relay input channels. Use dual-channel wiring for SIL 3 / PLe applications. Never wire directly to a motor contactor.

Testing: Press the e-stop and verify the machine stops within the required time. Test the reset mechanism. Repeat monthly per EN/ISO 13850.

Dimensions

Front 22.5mm cutout 40mm head Side panel terminals

Wiring Diagram

L T 21 22 NC (closed) opens on press

Troubleshooting

E-stop won't reset (twist/pull doesn't release)

Check for debris in the mechanism. For twist-release: turn clockwise 45-90 degrees. For push-pull: pull straight out firmly. If the mechanism is stuck, the internal latch may be damaged — replace the entire head assembly.

Machine doesn't stop when e-stop is pressed

Critical safety issue. Immediately lock out the machine. Check wiring — NC contacts must be in series with the safety relay. Verify the safety relay is functioning. A broken wire in an NC circuit should cause a stop, so check for a wiring bypass.

Safety relay faults after e-stop reset

The safety relay detects a cross-fault between the two monitoring channels. Check that both NC contacts on the e-stop are switching simultaneously. One contact may be welded closed — replace the contact block.

Quick Specs

Actuator
Knob, push-pull
Actuator Function
Maintained
Actuator Type
Mushroom Head
Certifications
UL, CSA, CE, IEC 60947-5-5
Color
Red

What People Are Saying

+

“M22-PV-K01 meets EN/ISO 13850 requirements. Always wire NC contacts through a safety relay, never direct to contactor. Test monthly.”

Reddit r/PLC 25 upvotes View thread →

Data Sources

Specifications and product data sourced from the following references.

M22-PV-K01 Eaton Product Page

https://www.eaton.com/us/en-us/skuPage.M22-PV-K01.html