ZB4-BZ101
نشطHarmony XB4 1NO Contact Block
Single contact block with 1 normally open (NO) contact for Schneider Harmony XB4 series. Screw clamp terminals.
التطبيقات الشائعة
Contact block that snaps onto the rear of any Schneider Harmony XB4 button head. The 1NO (Normally Open) contact closes the circuit when the button is pressed — standard for start, enable, and acknowledge functions. Rated for 6A at 120VAC, 10 million mechanical operations. When replacing a worn button, check the contact block first — if the button works intermittently, the contact block is usually the failed part, not the button head. One of the most-replaced components in industrial maintenance.
يوجد عادة في
التوافق
Fits all Schneider Harmony XB4 and XB5 button heads. Also fits legacy Telemecanique XB2 mounting. The ZBE-101 (element without base) stacks on top for dual-contact configurations. Not compatible with Eaton M22, ABB MP, or Siemens 3SU1 — those use their own contact blocks.
المواصفات
|
Certifications
Third-party safety certifications. UL = required for US NEC installations. CE = EU compliance. CSA = Canadian standards.
|
UL, CSA, CE
|
|
Contact Configuration
Normally Open — circuit is off until you press. Standard for start/go/enable functions.
|
1NO
|
|
Current rating
|
10A
|
|
Terminal Type
How you connect wires. Screw clamp is most common in industrial. Spring cage is faster but requires proper ferrules.
|
Screw Clamp
|
|
Max Voltage
|
600V
|
المواصفات بهذه الأيقونة مرتبطة بصفحة المصدر الأصلية للشركة المصنعة
ستحتاج أيضًا إلى
هذا مكون نمطي. للحصول على تجميع كامل، قد تحتاج أيضًا إلى:
بدائل متوافقة
هذه المنتجات هي مراجع تبادلية مكافئة وظيفيًا من شركات مصنعة أخرى.
مرجع سريع للتركيب
Mounting: Snap onto the rear of any compatible button body in the same series. The latch clicks audibly when properly seated. Some models require a mounting adapter.
Wiring: Terminals are marked NO (11/12) or NC (21/22). Use 0.5-2.5mm² wire with ferrules. Tighten to 0.8 Nm. Verify with a multimeter before energizing.
الأبعاد
مخطط التوصيل
استكشاف الأعطال وإصلاحها
Intermittent switching
Silver contacts are pitted from arcing. Replace the contact block — they are consumable parts. If arcing is severe, check that the switched load doesn't exceed the contact rating (typically 6A at 120VAC).
Contact block won't snap onto button body
Verify the contact block series matches the button head series (e.g., Schneider ZB4 blocks fit ZB4 heads only, not ZB5). Check for debris or damage on the mounting tabs.
أين تشتري
نطاق السعر
$1.64 — $19.64
عبر 4 موزع
مواصفات سريعة
- Certifications
- UL, CSA, CE
- Contact Configuration
- 1NO
- Current rating
- 10A
- Terminal Type
- Screw Clamp
- Max Voltage
- 600V
ما يقوله المستخدمون
“9 times out of 10 it is the contact block, not the button head. The silver contacts pit over time from arcing. Replace the ZB4-BZ101 (about $5) before replacing the whole assembly ($25+). Save yourself the trouble.”
“We schedule contact block replacements every 2 years on our high-cycle machines. The Schneider ZB4-BZ101 blocks are rated for 10M cycles but in a stamping press application they see that in about 18 months. Cheap insurance against nuisance faults.”
اعرف المزيد
مصادر البيانات
المواصفات وبيانات المنتج مأخوذة من المراجع التالية.