MCB-10
現行品Modular 1NO Contact Block
Single 1NO contact block for ABB Modular push button series. Snap-on mounting to operator heads. Screw terminals.
主な用途
Contact block from ABB's modular pilot device system. The 1NO contact closes the circuit when the button is pressed — standard for start, enable, and jog functions. Snaps onto the rear of any ABB MP-series push button head using the modular mounting system. The 10A/600V rating handles direct switching of small contactors and relay coils. When troubleshooting an intermittent button on an ABB panel, swap this block first — contact blocks wear faster than the button head and are the most common point of failure. Compatible with MP1, MP2, MP3, and MPET4 series actuators.
仕様一覧
|
Certifications
Third-party safety certifications. UL = required for US NEC installations. CE = EU compliance. CSA = Canadian standards.
|
UL, CSA, CE
|
|
Contact Configuration
Normally Open — circuit is off until you press. Standard for start/go/enable functions.
|
1NO
|
|
Current rating
|
10A
|
|
Terminal Type
How you connect wires. Screw clamp is most common in industrial. Spring cage is faster but requires proper ferrules.
|
Screw Clamp
|
|
Max Voltage
|
600V
|
このアイコン付きの仕様は、メーカーの元ソースページにリンクしています
併せて必要な部品
これはモジュール部品です。完全な組立には、以下も必要になる場合があります:
取付クイックリファレンス
Mounting: Snap onto the rear of any compatible button body in the same series. The latch clicks audibly when properly seated. Some models require a mounting adapter.
Wiring: Terminals are marked NO (11/12) or NC (21/22). Use 0.5-2.5mm² wire with ferrules. Tighten to 0.8 Nm. Verify with a multimeter before energizing.
外形寸法
配線図
トラブルシューティング
Intermittent switching
Silver contacts are pitted from arcing. Replace the contact block — they are consumable parts. If arcing is severe, check that the switched load doesn't exceed the contact rating (typically 6A at 120VAC).
Contact block won't snap onto button body
Verify the contact block series matches the button head series (e.g., Schneider ZB4 blocks fit ZB4 heads only, not ZB5). Check for debris or damage on the mounting tabs.
購入先
価格帯
$1.57 — $8.55
4 社の販売代理店
主要仕様
- Certifications
- UL, CSA, CE
- Contact Configuration
- 1NO
- Current rating
- 10A
- Terminal Type
- Screw Clamp
- Max Voltage
- 600V
ユーザーの声
“Keep spares of these. Contact blocks are consumable parts — the first thing to check when a button starts acting intermittent. Cheap replacement, saves troubleshooting time.”