Emergency Stop Switches / E-Stop Switches PUSHBUTTON,MAINTAINED,TW REL,RED,NON IL
Araştırma Notları
1. What this is
3SB22031AC01 is a Siemens 3SB2 16mm modular command switch (compact command/signalling device).
2. Part-number decode
- Series: 3SB2
- Panel cutout: 16mm
- Construction: modular (operator + holder + contact/lamp modules are separate parts)
3. Compatibility & ordering
Siemens 16mm command switches are modular IEC-style panel devices. Match by size, function (pushbutton/selector/indicator/E-stop), color, illumination, and contact blocks; cross-reference to Schneider Harmony, Allen-Bradley 800F, IDEC HW, or Eaton M22 by the same attributes if needed.
4. Data-quality note
The Siemens series is decoded from the part number (grounded in the Siemens LV1 catalog and distributor listings). The detailed configuration (exact function, color, contact arrangement, voltage) is encoded in the full order code and is left to the Siemens datasheet rather than guessed here. Flagged decoded-partial.
5. Sources
- Siemens LV1 catalog / SIRIUS ACT (3SU) & Class 52 selection data (siemens.com)
- Siemens Industry Mall — search the exact part/material number
- Distributor listing (Mouser / Newark) — search the exact part number
Kaynak
- Siemens Industry Mall — 3SB22031AC01 — siemens.com
Teknik Özellikler
|
Device class
|
command-switch
|
|
Enriched by
|
siemens-decoder-2026-08-12
|
|
Lead time
|
14 Days
|
|
Manufacturer series
|
3SB2
|
|
Modular
|
true
|
|
Mouser part number
|
982-3SB22031AC01
|
|
Panel cutout
|
16mm
|
|
Pn status
|
decoded-partial
|
|
Rohs status
|
RoHS Compliant
|
|
Series description
|
Siemens 3SB2 16mm modular command switch (compact command/signalling device)
|
Hızlı Montaj Kılavuzu
Panel cutout: 22mm. Mount with the yellow backing plate visible (required by EN/ISO 13850).
Wiring: Wire NC contacts in series with the safety relay input channels. Use dual-channel wiring for SIL 3 / PLe applications. Never wire directly to a motor contactor.
Testing: Press the e-stop and verify the machine stops within the required time. Test the reset mechanism. Repeat monthly per EN/ISO 13850.
Boyutlar
Sorun Giderme
E-stop won't reset (twist/pull doesn't release)
Check for debris in the mechanism. For twist-release: turn clockwise 45-90 degrees. For push-pull: pull straight out firmly. If the mechanism is stuck, the internal latch may be damaged — replace the entire head assembly.
Machine doesn't stop when e-stop is pressed
Critical safety issue. Immediately lock out the machine. Check wiring — NC contacts must be in series with the safety relay. Verify the safety relay is functioning. A broken wire in an NC circuit should cause a stop, so check for a wiring bypass.
Safety relay faults after e-stop reset
The safety relay detects a cross-fault between the two monitoring channels. Check that both NC contacts on the e-stop are switching simultaneously. One contact may be welded closed — replace the contact block.
Nereden Satın Alınır
Kısa Teknik Özellikler
- Device class
- command-switch
- Enriched by
- siemens-decoder-2026-08-12
- Lead time
- 14 Days
- Manufacturer series
- 3SB2
- Modular
- true