Yaygın Uygulamalar

Eaton equivalent of the Schneider XALD211. Green start + red stop in IP67 enclosure. Surface-mount for remote motor control. Same M22 quality in a pre-built package.

Teknik Özellikler

Certifications
UL, CSA, CE
Color
Green + Red
Contact Configuration
1NO + 1NC
IP Rating
IP67
Mounting Type
Surface mount (enclosed)
Series
M22

Hızlı Montaj Kılavuzu

Panel cutout: 22mm. Insert from the front of the panel, secure with mounting nut from behind (tighten to 2-3 Nm).

Contact block: Snap or screw the contact block onto the rear of the button body. Ensure the contact block orientation matches the wiring diagram — NO terminals are usually marked.

Wiring: Use 0.5-2.5mm² stranded wire with ferrules. Tighten screw terminals to 0.8 Nm. Test the button function before energizing the circuit.

Boyutlar

Bağlantı Şeması

11 12 NO 21 22 NC

Sorun Giderme

Button doesn't respond when pressed

Check the contact block first — it's the most common failure point. Test continuity across the NO or NC terminals with a multimeter. If no click is felt, the return spring in the head may be broken.

Works intermittently

Contact block contacts are pitted or burned. Replace the contact block — don't try to file the contacts. Check if the rated cycle count has been exceeded.

Button feels mushy or doesn't click

The spring return mechanism in the button head is worn. Replace the head. The contact block can usually be reused if it tests OK.

Nereden Satın Alınır

Fiyat aralığı

$3.13 — $141.76

2 distribütörde

Kısa Teknik Özellikler

Certifications
UL, CSA, CE
Color
Green + Red
Contact Configuration
1NO + 1NC
IP Rating
IP67
Mounting Type
Surface mount (enclosed)

Kullanıcı Görüşleri

+

“Eaton equivalent of the Schneider XALD211. Green start + red stop in IP67 enclosure. Surface-mount for remote motor control. Same M22 quality in a pre-built package.”

Reddit r/PLC 7 olumlu oy Konuyu görüntüle →