Allen-Bradley · 800F Серия

800F-2XA10-A1Y

В производстве
UL CSA

800F 2-Button Start/Stop Station Enclosed

Allen-Bradley 800F Серия Introduced circa 2005

Allen-Bradley 800F 2-button start/stop control station.

Типичные применения

Complete AB start/stop station in NEMA 4 enclosure. For remote motor control on US industrial equipment. Uses standard 800F buttons internally.

Характеристики

Certifications
UL, CSA
Color
Green + Red
Contact Configuration
1NO + 1NC
IP Rating
NEMA 4
Mounting Type
Surface mount (enclosed)

Краткое руководство по монтажу

Panel cutout: 22mm. Insert from the front of the panel, secure with mounting nut from behind (tighten to 2-3 Nm).

Contact block: Snap or screw the contact block onto the rear of the button body. Ensure the contact block orientation matches the wiring diagram — NO terminals are usually marked.

Wiring: Use 0.5-2.5mm² stranded wire with ferrules. Tighten screw terminals to 0.8 Nm. Test the button function before energizing the circuit.

Габаритные размеры

Схема подключения

11 12 NO 21 22 NC

Устранение неисправностей

Button doesn't respond when pressed

Check the contact block first — it's the most common failure point. Test continuity across the NO or NC terminals with a multimeter. If no click is felt, the return spring in the head may be broken.

Works intermittently

Contact block contacts are pitted or burned. Replace the contact block — don't try to file the contacts. Check if the rated cycle count has been exceeded.

Button feels mushy or doesn't click

The spring return mechanism in the button head is worn. Replace the head. The contact block can usually be reused if it tests OK.

Где купить

Диапазон цен

$137.42 — $170.58

у 2 дистрибьюторов

Краткие характеристики

Certifications
UL, CSA
Color
Green + Red
Contact Configuration
1NO + 1NC
IP Rating
NEMA 4
Mounting Type
Surface mount (enclosed)