ABB · MP Серия

MP4-10R

В производстве
UL CSA CE

22mm Red Mushroom Push Button 40mm

Артикул: MP - 4 - 10R
ABB MP Серия Introduced circa 2005

ABB 40mm red mushroom push button — momentary (not e-stop).

Типичные применения

40mm red mushroom for non-latching stop applications. Unlike an e-stop (which latches), this springs back when released. Used for cycle stop and machine pause where immediate restart after release is acceptable.

Характеристики

Actuator Function
Momentary
Actuator Type
Mushroom 40mm
Certifications
UL, CSA, CE
Color
Red
Cutout Diameter
22mm

Краткое руководство по монтажу

Panel cutout: 22mm. Insert from the front of the panel, secure with mounting nut from behind (tighten to 2-3 Nm).

Contact block: Snap or screw the contact block onto the rear of the button body. Ensure the contact block orientation matches the wiring diagram — NO terminals are usually marked.

Wiring: Use 0.5-2.5mm² stranded wire with ferrules. Tighten screw terminals to 0.8 Nm. Test the button function before energizing the circuit.

Габаритные размеры

Front 22mm cutout panel hole diameter Side panel contact ~45mm depth

Устранение неисправностей

Button doesn't respond when pressed

Check the contact block first — it's the most common failure point. Test continuity across the NO or NC terminals with a multimeter. If no click is felt, the return spring in the head may be broken.

Works intermittently

Contact block contacts are pitted or burned. Replace the contact block — don't try to file the contacts. Check if the rated cycle count has been exceeded.

Button feels mushy or doesn't click

The spring return mechanism in the button head is worn. Replace the head. The contact block can usually be reused if it tests OK.

Краткие характеристики

Actuator Function
Momentary
Actuator Type
Mushroom 40mm
Certifications
UL, CSA, CE
Color
Red
Cutout Diameter
22mm

Что говорят пользователи

+

“40mm red mushroom for non-latching stop applications. Unlike an e-stop (which latches), this springs back when released. Used for cycle stop and machine pause where immediate restart after release is ”

Reddit r/PLC 26 голосов Перейти к обсуждению →