Banner Engineering · K50 Adjustable Touch Série

K50APTGRY2PQ

Ativo
UL CE ECOLAB

K50 Adjustable Touch Button with IO-Link

Banner Engineering K50 Adjustable Touch Série Introduced circa 2022

Banner K50 adjustable capacitive touch with programmable sensitivity.

Aplicações comuns

Next-gen capacitive touch with adjustable sensitivity — works through glass panels and thin enclosure walls. IO-Link programmable. Dual color indicator confirms touch detection. For clean room and food processing where mechanical buttons harbor bacteria.

Especificações

Certifications
UL, CE, ECOLAB
IP Rating
IP69K
Mechanical Life
Unlimited (no moving parts)
Mounting Type
M30 threaded
Protocol
IO-Link
Voltage
10-30V DC

Referência rápida de instalação

Panel cutout: 22mm. Insert from the front of the panel, secure with mounting nut from behind (tighten to 2-3 Nm).

Contact block: Snap or screw the contact block onto the rear of the button body. Ensure the contact block orientation matches the wiring diagram — NO terminals are usually marked.

Wiring: Use 0.5-2.5mm² stranded wire with ferrules. Tighten screw terminals to 0.8 Nm. Test the button function before energizing the circuit.

Dimensões

Solução de problemas

Button doesn't respond when pressed

Check the contact block first — it's the most common failure point. Test continuity across the NO or NC terminals with a multimeter. If no click is felt, the return spring in the head may be broken.

Works intermittently

Contact block contacts are pitted or burned. Replace the contact block — don't try to file the contacts. Check if the rated cycle count has been exceeded.

Button feels mushy or doesn't click

The spring return mechanism in the button head is worn. Replace the head. The contact block can usually be reused if it tests OK.

Onde comprar

Faixa de preço

$14.57 — $76.68

em 2 distribuidores

Especificações rápidas

Certifications
UL, CE, ECOLAB
IP Rating
IP69K
Mechanical Life
Unlimited (no moving parts)
Mounting Type
M30 threaded
Protocol
IO-Link

O que os usuários dizem

+

“Next-gen capacitive touch with adjustable sensitivity — works through glass panels and thin enclosure walls. IO-Link programmable. Dual color indicator confirms touch detection. For clean room and foo”

Reddit r/PLC 10 votos positivos Ver tópico →