Imagem da série: o vendedor a utiliza para 2 outras peças também, portanto pode não mostrar esta versão exata.
Switch Actuators 30mm Illum Flush RED 110VAC/DC Momentary
Notas de Pesquisa
1. What this is
ALF4LB-110 is an Altech component — series not recognized.
2. Part-number decode
- Series: Altech Altech (series not recognized)
3. Compatibility & ordering
Altech 22/30mm pushbuttons are cost-effective IEC-style panel operators. Match by size (22mm), operator material (metal vs plastic), illumination (and voltage), action, and contact blocks; cross-reference to Schneider Harmony, Allen-Bradley 800F, Siemens 3SU, or Eaton M22 by the same attributes if needed.
4. Data-quality note
The exact Altech series/configuration could not be confidently decoded from this part number. Kept and documented; flagged needs-verification rather than guessed.
5. Sources
- Altech Corp datasheet / 22mm pushbutton tech specs (altechcorp.com)
- Distributor listing (Mouser / Future Electronics) — search the exact part number
Fonte
- Altech Corp — ALF4LB-110 — altechcorp.com
Especificações
|
Enriched by
|
altech-decoder-2026-08-12
|
|
Lead time
|
0 Days
|
|
Manufacturer series
|
Altech (series not recognized)
|
|
Mouser part number
|
845-ALF4LB-110
|
|
Pn status
|
needs-verification
|
|
Rohs status
|
RoHS Compliant
|
|
Series description
|
Altech Corp industrial control component — exact series/config could not be decoded from this part number; kept and flagged for verification rather than guessed
|
Referência rápida de instalação
Panel cutout: 22mm. Insert from the front of the panel, secure with mounting nut from behind (tighten to 2-3 Nm).
Contact block: Snap or screw the contact block onto the rear of the button body. Ensure the contact block orientation matches the wiring diagram — NO terminals are usually marked.
Wiring: Use 0.5-2.5mm² stranded wire with ferrules. Tighten screw terminals to 0.8 Nm. Test the button function before energizing the circuit.
Dimensões
Solução de problemas
Button doesn't respond when pressed
Check the contact block first — it's the most common failure point. Test continuity across the NO or NC terminals with a multimeter. If no click is felt, the return spring in the head may be broken.
Works intermittently
Contact block contacts are pitted or burned. Replace the contact block — don't try to file the contacts. Check if the rated cycle count has been exceeded.
Button feels mushy or doesn't click
The spring return mechanism in the button head is worn. Replace the head. The contact block can usually be reused if it tests OK.
Onde comprar
Especificações rápidas
- Enriched by
- altech-decoder-2026-08-12
- Lead time
- 0 Days
- Manufacturer series
- Altech (series not recognized)
- Mouser part number
- 845-ALF4LB-110
- Pn status
- needs-verification
Saiba mais
Graus de proteção IP explicados
O que IP65, IP66, IP67, IP69K significam para sua aplicação
Guia 22mm vs. 30mm
Qual tamanho de recorte de painel você precisa?
Blocos de contato: NO vs. NC
Como escolher e conectar blocos de contato
Ferramenta localizador de botões
Encontre o botão certo por tipo, tamanho e cor