PBES22L11M3R

현행 제품

TE Connectivity PBES22L11M3R

TE Connectivity PBES22L11M3R — TE Connectivity PBES22L11M3R

Emergency Stop Switches / E-Stop Switches PBES22 40 LED 230/240V AC/DC 1.2mA NO NC

Research Notes

1. What this is

PBES22L11M3R ("TE Connectivity PBES22L11M3R") is catalogued as a emergency-stop device from TE Connectivity.

2. What we know

  • Manufacturer: TE Connectivity
  • Category: emergency-stop device
  • Part number / name: PBES22L11M3R — TE Connectivity PBES22L11M3R
  • TE Connectivity — connectors, switches, and sensors for electronics and industrial use

3. How to identify / order the exact part

The full specifications for this part are not machine-decodable from the data we hold. To confirm the exact configuration (contacts, rating, colour, mounting, protocol), search the TE Connectivity catalog for this part number on the manufacturer site or a distributor (DigiKey / Mouser / RS).

4. Data-quality note

This page is generated from the catalogued manufacturer, category, and product name. Per our keep-and-document policy we publish a page for every part we hold and state plainly what is known versus what needs verification, rather than deleting the row or inventing specs. Flagged needs-verification.

5. Sources

  • TE Connectivity product catalog — search "PBES22L11M3R" / "TE Connectivity PBES22L11M3R"

1 source
  1. TE Connectivity PBES22L11M3R — distributor/catalog

사양 목록

Device class
emergency-stop
Enriched by
generic-fallback-2026-08-12
Lead time
150 Days
Mouser part number
655-PBES22L11M3R
Pn status
needs-verification
Rohs status
RoHS Compliant

설치 빠른 참조

Panel cutout: 22mm. Mount with the yellow backing plate visible (required by EN/ISO 13850).

Wiring: Wire NC contacts in series with the safety relay input channels. Use dual-channel wiring for SIL 3 / PLe applications. Never wire directly to a motor contactor.

Testing: Press the e-stop and verify the machine stops within the required time. Test the reset mechanism. Repeat monthly per EN/ISO 13850.

외형 치수

문제 해결

E-stop won't reset (twist/pull doesn't release)

Check for debris in the mechanism. For twist-release: turn clockwise 45-90 degrees. For push-pull: pull straight out firmly. If the mechanism is stuck, the internal latch may be damaged — replace the entire head assembly.

Machine doesn't stop when e-stop is pressed

Critical safety issue. Immediately lock out the machine. Check wiring — NC contacts must be in series with the safety relay. Verify the safety relay is functioning. A broken wire in an NC circuit should cause a stop, so check for a wiring bypass.

Safety relay faults after e-stop reset

The safety relay detects a cross-fault between the two monitoring channels. Check that both NC contacts on the e-stop are switching simultaneously. One contact may be welded closed — replace the contact block.

구매처

가격 범위

$23.64 — $23.64

1개 대리점

주요 사양

Device class
emergency-stop
Enriched by
generic-fallback-2026-08-12
Lead time
150 Days
Mouser part number
655-PBES22L11M3R
Pn status
needs-verification