Emergency Stop Switches / E-Stop Switches PBES22 40 LED 230/240V AC/DC 1.2mA NO NC
Research Notes
1. What this is
PBES22L11M3R ("TE Connectivity PBES22L11M3R") is catalogued as a emergency-stop device from TE Connectivity.
2. What we know
- Manufacturer: TE Connectivity
- Category: emergency-stop device
- Part number / name: PBES22L11M3R — TE Connectivity PBES22L11M3R
- TE Connectivity — connectors, switches, and sensors for electronics and industrial use
3. How to identify / order the exact part
The full specifications for this part are not machine-decodable from the data we hold. To confirm the exact configuration (contacts, rating, colour, mounting, protocol), search the TE Connectivity catalog for this part number on the manufacturer site or a distributor (DigiKey / Mouser / RS).
4. Data-quality note
This page is generated from the catalogued manufacturer, category, and product name. Per our keep-and-document policy we publish a page for every part we hold and state plainly what is known versus what needs verification, rather than deleting the row or inventing specs. Flagged needs-verification.
5. Sources
- TE Connectivity product catalog — search "PBES22L11M3R" / "TE Connectivity PBES22L11M3R"
1 source
- TE Connectivity PBES22L11M3R — distributor/catalog
Spesifikasi
|
Device class
|
emergency-stop
|
|
Enriched by
|
generic-fallback-2026-08-12
|
|
Lead time
|
150 Days
|
|
Mouser part number
|
655-PBES22L11M3R
|
|
Pn status
|
needs-verification
|
|
Rohs status
|
RoHS Compliant
|
Referensi Cepat Instalasi
Panel cutout: 22mm. Mount with the yellow backing plate visible (required by EN/ISO 13850).
Wiring: Wire NC contacts in series with the safety relay input channels. Use dual-channel wiring for SIL 3 / PLe applications. Never wire directly to a motor contactor.
Testing: Press the e-stop and verify the machine stops within the required time. Test the reset mechanism. Repeat monthly per EN/ISO 13850.
Dimensi
Pemecahan Masalah
E-stop won't reset (twist/pull doesn't release)
Check for debris in the mechanism. For twist-release: turn clockwise 45-90 degrees. For push-pull: pull straight out firmly. If the mechanism is stuck, the internal latch may be damaged — replace the entire head assembly.
Machine doesn't stop when e-stop is pressed
Critical safety issue. Immediately lock out the machine. Check wiring — NC contacts must be in series with the safety relay. Verify the safety relay is functioning. A broken wire in an NC circuit should cause a stop, so check for a wiring bypass.
Safety relay faults after e-stop reset
The safety relay detects a cross-fault between the two monitoring channels. Check that both NC contacts on the e-stop are switching simultaneously. One contact may be welded closed — replace the contact block.
Spesifikasi Cepat