ALW224602D-R

現行品

IDEC ALW224602D-R

型番: R
IDEC ALW224602D-R — IDEC ALW224602D-R

シリーズ画像: 販売者は74個の他の部品にも使用しているため、この正確なバージョンが表示されない場合があります。

Pushbutton Switches 22mm Pushbutton Illuminated

研究ノート

1. What this is

ALW224602D-R is an IDEC device — series not recognized.

2. Part-number decode

  • Series: IDEC IDEC (series not recognized) — command switch

3. Compatibility & ordering

Panel cutout: **. Unibody construction — the operator and contact are a single assembly. Cross-reference by size, operation, contact arrangement, and color to an equivalent from another IEC command-switch line (Schneider Harmony, Allen-Bradley 800F/800T, Siemens 3SU, Eaton M22) if IDEC is unavailable.

4. Data-quality note

The exact IDEC series/configuration could not be confidently decoded from this part number. It is kept and documented (not deleted) and flagged needs-verification rather than guessed — if you have the datasheet or a distributor listing, that is the authoritative source.

5. Sources

  • IDEC IDEC (series not recognized)-series datasheet / ordering guide (idec.com)
  • IDEC USA catalog: https://us.idec.com (search the exact part number)

出典
  1. IDEC USA catalog — ALW224602D-R — us.idec.com

仕様一覧

Enriched by
idec-decoder-2026-08-12
Lead time
0 Days
Manufacturer series
IDEC (series not recognized)
Mouser part number
199-ALW224602DR
Pn status
needs-verification
Rohs status
Series description
IDEC industrial command switch — the exact series/config could not be decoded from this part number; kept and flagged for verification rather than guessed

取付クイックリファレンス

Panel cutout: 22mm. Insert from the front of the panel, secure with mounting nut from behind (tighten to 2-3 Nm).

Contact block: Snap or screw the contact block onto the rear of the button body. Ensure the contact block orientation matches the wiring diagram — NO terminals are usually marked.

Wiring: Use 0.5-2.5mm² stranded wire with ferrules. Tighten screw terminals to 0.8 Nm. Test the button function before energizing the circuit.

外形寸法

トラブルシューティング

Button doesn't respond when pressed

Check the contact block first — it's the most common failure point. Test continuity across the NO or NC terminals with a multimeter. If no click is felt, the return spring in the head may be broken.

Works intermittently

Contact block contacts are pitted or burned. Replace the contact block — don't try to file the contacts. Check if the rated cycle count has been exceeded.

Button feels mushy or doesn't click

The spring return mechanism in the button head is worn. Replace the head. The contact block can usually be reused if it tests OK.

写真と図面

画像: mouser.com

主要仕様

Enriched by
idec-decoder-2026-08-12
Lead time
0 Days
Manufacturer series
IDEC (series not recognized)
Mouser part number
199-ALW224602DR
Pn status
needs-verification