Tootenumber: 3SU1 - 1 - 30
Siemens SIRIUS ACT Seeria Introduced circa 2013

Siemens SIRIUS ACT illuminated yellow flush.

Tüüpilised rakendused

Yellow illuminated for caution/warning. Metal front ring. Completes the Siemens illuminated range.

Spetsifikatsioonid

Certifications
UL, CSA, CE
Color
Yellow
Contact Configuration
1NO
Cutout Diameter
22mm
Illumination
Illuminated
IP Rating
IP67
LED Voltage
24V AC/DC
Material
Metal front ring

Paigalduse kiirjuhend

Panel cutout: 22mm. Insert from the front of the panel, secure with mounting nut from behind (tighten to 2-3 Nm).

Contact block: Snap or screw the contact block onto the rear of the button body. Ensure the contact block orientation matches the wiring diagram — NO terminals are usually marked.

Wiring: Use 0.5-2.5mm² stranded wire with ferrules. Tighten screw terminals to 0.8 Nm. Test the button function before energizing the circuit.

Mõõtmed

Front 22mm cutout panel hole diameter Side panel contact ~45mm depth

Ühenduseskeem

L T 11 12 NO (open) press ↓

Veaotsing

Button doesn't respond when pressed

Check the contact block first — it's the most common failure point. Test continuity across the NO or NC terminals with a multimeter. If no click is felt, the return spring in the head may be broken.

Works intermittently

Contact block contacts are pitted or burned. Replace the contact block — don't try to file the contacts. Check if the rated cycle count has been exceeded.

Button feels mushy or doesn't click

The spring return mechanism in the button head is worn. Replace the head. The contact block can usually be reused if it tests OK.

Kust osta

Hinnavahemik

$89.95 — $109.74

2 edasimüüja juures

Kiirspetsifikatsioonid

Certifications
UL, CSA, CE
Color
Yellow
Contact Configuration
1NO
Cutout Diameter
22mm
Illumination
Illuminated

Mida kasutajad ütlevad

“Yellow illuminated for caution/warning. Metal front ring. Completes the Siemens illuminated range.”

Reddit r/PLC 29 poolthääli Vaata arutelu →