Eaton · M22 Seeria

M22-I1-M1

Aktiivne
UL CSA CE

M22 1-Button Green Start Station Enclosed

Tootenumber: M22
Eaton M22 Seeria Introduced circa 2005

Eaton M22 enclosed single-button control station.

Tüüpilised rakendused

Complete start station: M22 green button in an IP67 sealed enclosure with cable gland. Surface-mount for remote locations. The Eaton equivalent of Schneider XALK.

Spetsifikatsioonid

Certifications
UL, CSA, CE
Color
Green
Contact Configuration
1NO
IP Rating
IP67
Mounting Type
Surface mount (enclosed)
Series
M22

Paigalduse kiirjuhend

Panel cutout: 22mm. Insert from the front of the panel, secure with mounting nut from behind (tighten to 2-3 Nm).

Contact block: Snap or screw the contact block onto the rear of the button body. Ensure the contact block orientation matches the wiring diagram — NO terminals are usually marked.

Wiring: Use 0.5-2.5mm² stranded wire with ferrules. Tighten screw terminals to 0.8 Nm. Test the button function before energizing the circuit.

Mõõtmed

Ühenduseskeem

L T 11 12 NO (open) press ↓

Veaotsing

Button doesn't respond when pressed

Check the contact block first — it's the most common failure point. Test continuity across the NO or NC terminals with a multimeter. If no click is felt, the return spring in the head may be broken.

Works intermittently

Contact block contacts are pitted or burned. Replace the contact block — don't try to file the contacts. Check if the rated cycle count has been exceeded.

Button feels mushy or doesn't click

The spring return mechanism in the button head is worn. Replace the head. The contact block can usually be reused if it tests OK.

Kust osta

Hinnavahemik

$65.1 — $108.55

2 edasimüüja juures

Kiirspetsifikatsioonid

Certifications
UL, CSA, CE
Color
Green
Contact Configuration
1NO
IP Rating
IP67
Mounting Type
Surface mount (enclosed)

Mida kasutajad ütlevad

“Complete start station: M22 green button in an IP67 sealed enclosure with cable gland. Surface-mount for remote locations. The Eaton equivalent of Schneider XALK.”

Reddit r/PLC 10 poolthääli Vaata arutelu →