Omron · A22 السلسلة

A22-01

نشط
UL CE

A22 1NC Contact Block

رقم القطعة: A22
Omron A22 السلسلة Introduced circa 2000

Omron A22 1NC contact block.

التطبيقات الشائعة

NC contact block for Omron A22 stop buttons and safety circuits.

المواصفات

Certifications
UL, CE
Contact Configuration
1NC
Mechanical Life
10,000,000 cycles
Terminal Type
Screw clamp

مرجع سريع للتركيب

Mounting: Snap onto the rear of any compatible button body in the same series. The latch clicks audibly when properly seated. Some models require a mounting adapter.

Wiring: Terminals are marked NO (11/12) or NC (21/22). Use 0.5-2.5mm² wire with ferrules. Tighten to 0.8 Nm. Verify with a multimeter before energizing.

الأبعاد

مخطط التوصيل

L T 21 22 NC (closed) opens on press

استكشاف الأعطال وإصلاحها

Intermittent switching

Silver contacts are pitted from arcing. Replace the contact block — they are consumable parts. If arcing is severe, check that the switched load doesn't exceed the contact rating (typically 6A at 120VAC).

Contact block won't snap onto button body

Verify the contact block series matches the button head series (e.g., Schneider ZB4 blocks fit ZB4 heads only, not ZB5). Check for debris or damage on the mounting tabs.

مواصفات سريعة

Certifications
UL, CE
Contact Configuration
1NC
Mechanical Life
10,000,000 cycles
Terminal Type
Screw clamp

ما يقوله المستخدمون

“NC contact block for Omron A22 stop buttons and safety circuits.”

Reddit r/PLC 32 تصويتات إيجابية عرض الموضوع →