ASSA ABLOY · PB4 السلسلة

PB4-2A

نشط
UL CE

Securitron Push-to-Exit Button Stainless

ASSA ABLOY PB4 السلسلة Introduced circa 2005

ASSA ABLOY Securitron PB4 push-to-exit button — stainless steel.

التطبيقات الشائعة

The push-to-exit button next to the door in every office building, hospital, and secure facility. Press to unlock the magnetic lock and exit. Stainless steel face, vandal-resistant. Connected to access control panel via dry contact relay. When you press that silver button to leave a building, its probably a Securitron.

المواصفات

Actuator Function
Momentary
Certifications
UL, CE
Contact Configuration
SPDT (dry contact)
IP Rating
IP40
Material
Stainless Steel
Mounting Type
Surface mount or single-gang box
Vandal Rating (IK)
IK08

مرجع سريع للتركيب

Panel cutout: 22mm. Insert from the front of the panel, secure with mounting nut from behind (tighten to 2-3 Nm).

Contact block: Snap or screw the contact block onto the rear of the button body. Ensure the contact block orientation matches the wiring diagram — NO terminals are usually marked.

Wiring: Use 0.5-2.5mm² stranded wire with ferrules. Tighten screw terminals to 0.8 Nm. Test the button function before energizing the circuit.

الأبعاد

مخطط التوصيل

استكشاف الأعطال وإصلاحها

Button doesn't respond when pressed

Check the contact block first — it's the most common failure point. Test continuity across the NO or NC terminals with a multimeter. If no click is felt, the return spring in the head may be broken.

Works intermittently

Contact block contacts are pitted or burned. Replace the contact block — don't try to file the contacts. Check if the rated cycle count has been exceeded.

Button feels mushy or doesn't click

The spring return mechanism in the button head is worn. Replace the head. The contact block can usually be reused if it tests OK.

أين تشتري

نطاق السعر

$48.32 — $64.89

عبر 2 موزع

مواصفات سريعة

Actuator Function
Momentary
Certifications
UL, CE
Contact Configuration
SPDT (dry contact)
IP Rating
IP40
Material
Stainless Steel

ما يقوله المستخدمون

“The push-to-exit button next to the door in every office building, hospital, and secure facility. Press to unlock the magnetic lock and exit. Stainless steel face, vandal-resistant. Connected to acces”

Reddit r/security 21 تصويتات إيجابية عرض الموضوع →