ZA2BS944

在产

Schneider Electric ZA2BS944

零件编号: B - S - 844
Schneider Electric ZA2BS944 — Schneider Electric ZA2BS944

Emergency Stop Switches / E-Stop Switches MUSHROOM/40MM RED T-T-R

Research Notes

1. What this is

ZA2BS944 is a Schneider Electric Harmony ZA2 (older generation) 22mm modular component (operator head / contact block).

2. Part-number decode

  • Series: Harmony ZA2
  • Panel cutout: 22mm
  • Type: head/block (modular)

3. Compatibility & ordering

Schneider's Harmony (22/16mm) and Square D Class 9001 (30mm) are the reference IEC/US command-switch ranges. This is a modular component — a Harmony/9001 device is assembled from an operator head + mounting collar + contact/light block(s). Confirm you have the matching head and blocks for a complete device. Match by size (16/22/30mm), bezel material (metal XB4/ZB4 vs plastic XB5/ZB5), function (pushbutton/selector/indicator/E-stop), colour, illumination, and contact arrangement; cross-reference to Allen-Bradley 800F/800T, Siemens 3SU, IDEC HW, or Eaton M22 by the same attributes if needed.

4. Data-quality note

The Schneider series/family is identified; bezel/size are indicative and the exact colour/contact configuration is left to the Schneider datasheet rather than guessed. Flagged decoded-partial.

5. Sources

  • Schneider Electric Harmony / Square D Class 9001 catalog (se.com)
  • Distributor listing (Rexel / Mouser / Newark) — search the exact part number

1 source
  1. Schneider Electric — ZA2BS944 — se.com

规格参数

Component type
head/block (modular)
Enriched by
schneider-decoder-2026-08-12
Lead time
0 Days
Manufacturer series
Harmony ZA2
Mouser part number
996-ZA2BS944
Panel cutout
22mm
Pn status
decoded-partial
Wireless Range
Harmony / Square D Class 9001
Rohs status
Series description
Schneider Harmony ZA2 (older generation) 22mm modular component (operator head / contact block)

安装快速参考

Panel cutout: 22mm. Mount with the yellow backing plate visible (required by EN/ISO 13850).

Wiring: Wire NC contacts in series with the safety relay input channels. Use dual-channel wiring for SIL 3 / PLe applications. Never wire directly to a motor contactor.

Testing: Press the e-stop and verify the machine stops within the required time. Test the reset mechanism. Repeat monthly per EN/ISO 13850.

尺寸

故障排除

E-stop won't reset (twist/pull doesn't release)

Check for debris in the mechanism. For twist-release: turn clockwise 45-90 degrees. For push-pull: pull straight out firmly. If the mechanism is stuck, the internal latch may be damaged — replace the entire head assembly.

Machine doesn't stop when e-stop is pressed

Critical safety issue. Immediately lock out the machine. Check wiring — NC contacts must be in series with the safety relay. Verify the safety relay is functioning. A broken wire in an NC circuit should cause a stop, so check for a wiring bypass.

Safety relay faults after e-stop reset

The safety relay detects a cross-fault between the two monitoring channels. Check that both NC contacts on the e-stop are switching simultaneously. One contact may be welded closed — replace the contact block.

购买渠道

价格范围

$87.23 — $87.23

来自 1 家经销商

快速规格

Component type
head/block (modular)
Enriched by
schneider-decoder-2026-08-12
Lead time
0 Days
Manufacturer series
Harmony ZA2
Mouser part number
996-ZA2BS944