Emergency Stop Switches / E-Stop Switches 16mm Emergency-Stop
Research Notes
1. What this is
HA1B-V2E1R is an IDEC device — series not recognized.
2. Part-number decode
- Series: IDEC IDEC (series not recognized) — command switch
3. Compatibility & ordering
Panel cutout: **. Unibody construction — the operator and contact are a single assembly. Cross-reference by size, operation, contact arrangement, and color to an equivalent from another IEC command-switch line (Schneider Harmony, Allen-Bradley 800F/800T, Siemens 3SU, Eaton M22) if IDEC is unavailable.
4. Data-quality note
The exact IDEC series/configuration could not be confidently decoded from this part number. It is kept and documented (not deleted) and flagged needs-verification rather than guessed — if you have the datasheet or a distributor listing, that is the authoritative source.
5. Sources
- IDEC IDEC (series not recognized)-series datasheet / ordering guide (idec.com)
- IDEC USA catalog: https://us.idec.com (search the exact part number)
1 source
- IDEC USA catalog — HA1B-V2E1R — us.idec.com
规格参数
|
Enriched by
|
idec-decoder-2026-08-12
|
|
Lead time
|
0 Days
|
|
Manufacturer series
|
IDEC (series not recognized)
|
|
Mouser part number
|
199-HA1BV2E1R
|
|
Pn status
|
needs-verification
|
|
Rohs status
|
|
|
Series description
|
IDEC industrial command switch — the exact series/config could not be decoded from this part number; kept and flagged for verification rather than guessed
|
安装快速参考
Panel cutout: 22mm. Mount with the yellow backing plate visible (required by EN/ISO 13850).
Wiring: Wire NC contacts in series with the safety relay input channels. Use dual-channel wiring for SIL 3 / PLe applications. Never wire directly to a motor contactor.
Testing: Press the e-stop and verify the machine stops within the required time. Test the reset mechanism. Repeat monthly per EN/ISO 13850.
尺寸
故障排除
E-stop won't reset (twist/pull doesn't release)
Check for debris in the mechanism. For twist-release: turn clockwise 45-90 degrees. For push-pull: pull straight out firmly. If the mechanism is stuck, the internal latch may be damaged — replace the entire head assembly.
Machine doesn't stop when e-stop is pressed
Critical safety issue. Immediately lock out the machine. Check wiring — NC contacts must be in series with the safety relay. Verify the safety relay is functioning. A broken wire in an NC circuit should cause a stop, so check for a wiring bypass.
Safety relay faults after e-stop reset
The safety relay detects a cross-fault between the two monitoring channels. Check that both NC contacts on the e-stop are switching simultaneously. One contact may be welded closed — replace the contact block.
快速规格
- Enriched by
- idec-decoder-2026-08-12
- Lead time
- 0 Days
- Manufacturer series
- IDEC (series not recognized)
- Mouser part number
- 199-HA1BV2E1R
- Pn status
- needs-verification