6310-AAAG
在产Spa/Pool Air Switch
Herga air switch — pneumatic push button for wet environments.
常见应用
Found on the rim of every hot tub and spa in the world. Air switches use pneumatic pressure instead of electrical contacts at the push point — you press a button that sends an air pulse through a tube to a remote electrical switch. This means zero electricity at the point of contact in a wet environment. Also used on food processing equipment and underwater lighting controls.
规格参数
|
Actuator Function
Momentary = springs back when released. Maintained/latching = stays pressed until pressed again.
|
Momentary
|
|
Certifications
Third-party safety certifications. UL = required for US NEC installations. CE = EU compliance. CSA = Canadian standards.
|
UL, CE, NSF
|
|
Contact Configuration
The electrical switching arrangement.
|
SPST (air-actuated)
|
|
Material
The bezel/body material. Metal bezels are more durable in harsh environments. Plastic is lighter and cheaper.
|
ABS plastic
|
安装快速参考
Panel cutout: 22mm. Insert from the front of the panel, secure with mounting nut from behind (tighten to 2-3 Nm).
Contact block: Snap or screw the contact block onto the rear of the button body. Ensure the contact block orientation matches the wiring diagram — NO terminals are usually marked.
Wiring: Use 0.5-2.5mm² stranded wire with ferrules. Tighten screw terminals to 0.8 Nm. Test the button function before energizing the circuit.
尺寸
接线图
故障排除
Button doesn't respond when pressed
Check the contact block first — it's the most common failure point. Test continuity across the NO or NC terminals with a multimeter. If no click is felt, the return spring in the head may be broken.
Works intermittently
Contact block contacts are pitted or burned. Replace the contact block — don't try to file the contacts. Check if the rated cycle count has been exceeded.
Button feels mushy or doesn't click
The spring return mechanism in the button head is worn. Replace the head. The contact block can usually be reused if it tests OK.
快速规格
- Actuator Function
- Momentary
- Certifications
- UL, CE, NSF
- Contact Configuration
- SPST (air-actuated)
- Material
- ABS plastic
用户评价