E34GDBC2N8-51

在产

Eaton Electrical E34GDBC2N8-51

Eaton Electrical E34GDBC2N8-51 — Eaton Electrical E34GDBC2N8-51

Emergency Stop Switches / E-Stop Switches PUSH PULLS

Research Notes

1. What this is

E34GDBC2N8-51 is an Eaton E34 30.5mm heavy-duty indicator / pilot-light family.

2. Part-number decode

  • Series: E34
  • Panel cutout: 30.5mm
  • Type: indicator

3. Compatibility & ordering

Eaton's M22 (RMQ-Titan, 22mm) and E30 / 10250T (30.5mm heavy-duty) are its principal command-switch ranges. This is a complete/integrated device. Match by size (22 / 30.5mm), function (pushbutton/selector/indicator/E-stop), color, illumination, and contact arrangement; cross-reference to Schneider Harmony, Allen-Bradley 800F/800T, Siemens 3SU, or IDEC HW by the same attributes if needed.

4. Data-quality note

The Eaton series/family is identified; the exact configuration (color, contact, function) is left to the Eaton datasheet rather than guessed. Flagged decoded-partial.

5. Sources

  • Eaton control-components catalog (Vol.7) / RMQ-Titan M22 & 10250T (eaton.com)
  • Distributor listing (Newark / Mouser) — search the exact part number

1 source
  1. Eaton — E34GDBC2N8-51 — eaton.com

规格参数

Component type
indicator
Device class
indicator
Enriched by
eaton-decoder-2026-08-12
Lead time
0 Days
Manufacturer series
E34
Mouser part number
504-E34GDBC2N8-51
Panel cutout
30.5mm
Pn status
decoded-partial
Rohs status
Series description
Eaton E34 30.5mm heavy-duty indicator / pilot-light family

安装快速参考

Panel cutout: 22mm. Mount with the yellow backing plate visible (required by EN/ISO 13850).

Wiring: Wire NC contacts in series with the safety relay input channels. Use dual-channel wiring for SIL 3 / PLe applications. Never wire directly to a motor contactor.

Testing: Press the e-stop and verify the machine stops within the required time. Test the reset mechanism. Repeat monthly per EN/ISO 13850.

尺寸

故障排除

E-stop won't reset (twist/pull doesn't release)

Check for debris in the mechanism. For twist-release: turn clockwise 45-90 degrees. For push-pull: pull straight out firmly. If the mechanism is stuck, the internal latch may be damaged — replace the entire head assembly.

Machine doesn't stop when e-stop is pressed

Critical safety issue. Immediately lock out the machine. Check wiring — NC contacts must be in series with the safety relay. Verify the safety relay is functioning. A broken wire in an NC circuit should cause a stop, so check for a wiring bypass.

Safety relay faults after e-stop reset

The safety relay detects a cross-fault between the two monitoring channels. Check that both NC contacts on the e-stop are switching simultaneously. One contact may be welded closed — replace the contact block.

购买渠道

价格范围

$195.82 — $195.82

来自 1 家经销商

快速规格

Component type
indicator
Device class
indicator
Enriched by
eaton-decoder-2026-08-12
Lead time
0 Days
Manufacturer series
E34