Emergency Stop Switches / E-Stop Switches PUSH-PULL OPERATOR
Research Notes
1. What this is
E34GDBC2N8-51X is an Eaton E34 30.5mm heavy-duty indicator / pilot-light family.
2. Part-number decode
- Series: E34
- Panel cutout: 30.5mm
- Type: indicator
3. Compatibility & ordering
Eaton's M22 (RMQ-Titan, 22mm) and E30 / 10250T (30.5mm heavy-duty) are its principal command-switch ranges. This is a complete/integrated device. Match by size (22 / 30.5mm), function (pushbutton/selector/indicator/E-stop), color, illumination, and contact arrangement; cross-reference to Schneider Harmony, Allen-Bradley 800F/800T, Siemens 3SU, or IDEC HW by the same attributes if needed.
4. Data-quality note
The Eaton series/family is identified; the exact configuration (color, contact, function) is left to the Eaton datasheet rather than guessed. Flagged decoded-partial.
5. Sources
- Eaton control-components catalog (Vol.7) / RMQ-Titan M22 & 10250T (eaton.com)
- Distributor listing (Newark / Mouser) — search the exact part number
1 source
- Eaton — E34GDBC2N8-51X — eaton.com
Teknik Özellikler
|
Component type
|
indicator
|
|
Device class
|
indicator
|
|
Enriched by
|
eaton-decoder-2026-08-12
|
|
Lead time
|
0 Days
|
|
Manufacturer series
|
E34
|
|
Mouser part number
|
504-E34GDBC2N8-51X
|
|
Panel cutout
|
30.5mm
|
|
Pn status
|
decoded-partial
|
|
Rohs status
|
|
|
Series description
|
Eaton E34 30.5mm heavy-duty indicator / pilot-light family
|
Hızlı Montaj Kılavuzu
Panel cutout: 22mm. Mount with the yellow backing plate visible (required by EN/ISO 13850).
Wiring: Wire NC contacts in series with the safety relay input channels. Use dual-channel wiring for SIL 3 / PLe applications. Never wire directly to a motor contactor.
Testing: Press the e-stop and verify the machine stops within the required time. Test the reset mechanism. Repeat monthly per EN/ISO 13850.
Boyutlar
Sorun Giderme
E-stop won't reset (twist/pull doesn't release)
Check for debris in the mechanism. For twist-release: turn clockwise 45-90 degrees. For push-pull: pull straight out firmly. If the mechanism is stuck, the internal latch may be damaged — replace the entire head assembly.
Machine doesn't stop when e-stop is pressed
Critical safety issue. Immediately lock out the machine. Check wiring — NC contacts must be in series with the safety relay. Verify the safety relay is functioning. A broken wire in an NC circuit should cause a stop, so check for a wiring bypass.
Safety relay faults after e-stop reset
The safety relay detects a cross-fault between the two monitoring channels. Check that both NC contacts on the e-stop are switching simultaneously. One contact may be welded closed — replace the contact block.
Nereden Satın Alınır
Fiyat aralığı
$195.82 — $195.82
1 distribütörde
Kısa Teknik Özellikler
- Component type
- indicator
- Device class
- indicator
- Enriched by
- eaton-decoder-2026-08-12
- Lead time
- 0 Days
- Manufacturer series
- E34