Emergency Stop Switches / E-Stop Switches 30MM PU-REL RED,2 NC
Research Notes
1. What this is
CE3P-10R-02 is a ABB CE command switch.
2. Part-number decode
- Series: ABB CE3/CE4
- Type: command switch
- Panel cutout: 22mm
3. Compatibility & ordering
ABB makes Modular (MP metal / CP plastic) 22mm command switches, CE compact switches, KP mushroom operators, and Jokab (2TLA) safety products. Match by type, actuation, illumination, sealing, and mounting, then use the manufacturer datasheet to confirm the exact contact and termination encoded in the part number.
4. Data-quality note
The ABB product line/type is identified; the detailed configuration is left to the datasheet rather than guessed. Flagged decoded-partial.
5. Sources
- ABB product catalog (abb.com)
- Distributor listing (DigiKey / Mouser) — search the exact part number
1 source
- ABB — CE3P-10R-02 — abb.com
Teknik Özellikler
|
Device class
|
command switch
|
|
Enriched by
|
abb-decoder-2026-08-12
|
|
Lead time
|
97 Days
|
|
Manufacturer series
|
CE3/CE4
|
|
Mouser part number
|
894-CE3P-10R-02
|
|
Panel cutout
|
22mm
|
|
Pn status
|
decoded-partial
|
|
Rohs status
|
|
|
Series description
|
ABB CE-series 22mm modular command switch (compact pushbutton/indicator; operator + contact block)
|
Hızlı Montaj Kılavuzu
Panel cutout: 22mm. Mount with the yellow backing plate visible (required by EN/ISO 13850).
Wiring: Wire NC contacts in series with the safety relay input channels. Use dual-channel wiring for SIL 3 / PLe applications. Never wire directly to a motor contactor.
Testing: Press the e-stop and verify the machine stops within the required time. Test the reset mechanism. Repeat monthly per EN/ISO 13850.
Boyutlar
Sorun Giderme
E-stop won't reset (twist/pull doesn't release)
Check for debris in the mechanism. For twist-release: turn clockwise 45-90 degrees. For push-pull: pull straight out firmly. If the mechanism is stuck, the internal latch may be damaged — replace the entire head assembly.
Machine doesn't stop when e-stop is pressed
Critical safety issue. Immediately lock out the machine. Check wiring — NC contacts must be in series with the safety relay. Verify the safety relay is functioning. A broken wire in an NC circuit should cause a stop, so check for a wiring bypass.
Safety relay faults after e-stop reset
The safety relay detects a cross-fault between the two monitoring channels. Check that both NC contacts on the e-stop are switching simultaneously. One contact may be welded closed — replace the contact block.
Nereden Satın Alınır
Fiyat aralığı
$28.56 — $28.56
1 distribütörde
Kısa Teknik Özellikler
- Device class
- command switch
- Enriched by
- abb-decoder-2026-08-12
- Lead time
- 97 Days
- Manufacturer series
- CE3/CE4
- Mouser part number
- 894-CE3P-10R-02