Emergency Stop Switches / E-Stop Switches 16mm X6 E-Stop 40mm 1NC
ข้อมูลจำเพาะ
|
Device class
|
emergency-stop
|
|
Enriched by
|
idec-decoder-2026-08-12
|
|
Lead time
|
0 Days
|
|
Manufacturer series
|
X6/AB6
|
|
Modular
|
false
|
|
Mouser part number
|
199-AB6E4BV01PTRH
|
|
Operation
|
Maintained (pushlock; turn or pull to reset)
|
|
Panel cutout
|
16mm
|
|
Pn status
|
decoded
|
|
Rohs status
|
RoHS Compliant
|
|
Series description
|
IDEC AB6E (X6-series) 16mm unibody emergency-stop switch (30mm mushroom head, direct-opening NC safety contact)
|
คู่มือการติดตั้งอย่างรวดเร็ว
Panel cutout: 22mm. Mount with the yellow backing plate visible (required by EN/ISO 13850).
Wiring: Wire NC contacts in series with the safety relay input channels. Use dual-channel wiring for SIL 3 / PLe applications. Never wire directly to a motor contactor.
Testing: Press the e-stop and verify the machine stops within the required time. Test the reset mechanism. Repeat monthly per EN/ISO 13850.
ขนาด
การแก้ไขปัญหา
E-stop won't reset (twist/pull doesn't release)
Check for debris in the mechanism. For twist-release: turn clockwise 45-90 degrees. For push-pull: pull straight out firmly. If the mechanism is stuck, the internal latch may be damaged — replace the entire head assembly.
Machine doesn't stop when e-stop is pressed
Critical safety issue. Immediately lock out the machine. Check wiring — NC contacts must be in series with the safety relay. Verify the safety relay is functioning. A broken wire in an NC circuit should cause a stop, so check for a wiring bypass.
Safety relay faults after e-stop reset
The safety relay detects a cross-fault between the two monitoring channels. Check that both NC contacts on the e-stop are switching simultaneously. One contact may be welded closed — replace the contact block.