AXWN-401-R

В производстве

IDEC AXWN-401-R

Артикул: R
IDEC AXWN-401-R — IDEC AXWN-401-R

Emergency Stop Switches / E-Stop Switches TWN PUSH-LOCK SW

Research Notes

1. What this is

AXWN-401-R is an IDEC device — series not recognized.

2. Part-number decode

  • Series: IDEC IDEC (series not recognized) — command switch

3. Compatibility & ordering

Panel cutout: **. Unibody construction — the operator and contact are a single assembly. Cross-reference by size, operation, contact arrangement, and color to an equivalent from another IEC command-switch line (Schneider Harmony, Allen-Bradley 800F/800T, Siemens 3SU, Eaton M22) if IDEC is unavailable.

4. Data-quality note

The exact IDEC series/configuration could not be confidently decoded from this part number. It is kept and documented (not deleted) and flagged needs-verification rather than guessed — if you have the datasheet or a distributor listing, that is the authoritative source.

5. Sources

  • IDEC IDEC (series not recognized)-series datasheet / ordering guide (idec.com)
  • IDEC USA catalog: https://us.idec.com (search the exact part number)

1 source
  1. IDEC USA catalog — AXWN-401-R — us.idec.com

Характеристики

Enriched by
idec-decoder-2026-08-12
Lead time
0 Days
Manufacturer series
IDEC (series not recognized)
Mouser part number
199-AXWN401R
Pn status
needs-verification
Rohs status
Series description
IDEC industrial command switch — the exact series/config could not be decoded from this part number; kept and flagged for verification rather than guessed

Краткое руководство по монтажу

Panel cutout: 22mm. Mount with the yellow backing plate visible (required by EN/ISO 13850).

Wiring: Wire NC contacts in series with the safety relay input channels. Use dual-channel wiring for SIL 3 / PLe applications. Never wire directly to a motor contactor.

Testing: Press the e-stop and verify the machine stops within the required time. Test the reset mechanism. Repeat monthly per EN/ISO 13850.

Габаритные размеры

Устранение неисправностей

E-stop won't reset (twist/pull doesn't release)

Check for debris in the mechanism. For twist-release: turn clockwise 45-90 degrees. For push-pull: pull straight out firmly. If the mechanism is stuck, the internal latch may be damaged — replace the entire head assembly.

Machine doesn't stop when e-stop is pressed

Critical safety issue. Immediately lock out the machine. Check wiring — NC contacts must be in series with the safety relay. Verify the safety relay is functioning. A broken wire in an NC circuit should cause a stop, so check for a wiring bypass.

Safety relay faults after e-stop reset

The safety relay detects a cross-fault between the two monitoring channels. Check that both NC contacts on the e-stop are switching simultaneously. One contact may be welded closed — replace the contact block.

Где купить

Диапазон цен

$33.84 — $33.84

у 1 дистрибьюторов

Краткие характеристики

Enriched by
idec-decoder-2026-08-12
Lead time
0 Days
Manufacturer series
IDEC (series not recognized)
Mouser part number
199-AXWN401R
Pn status
needs-verification