10250T5B62-S112

Activ

Eaton Electrical 10250T5B62-S112

Eaton Electrical 10250T5B62-S112 — Eaton Electrical 10250T5B62-S112

Emergency Stop Switches / E-Stop Switches PUSH-PULL PUSHBUTTON SWITCH

Research Notes

1. What this is

10250T5B62-S112 is an Eaton Cutler-Hammer 10250T 30.5mm HEAVY-DUTY pushbutton / indicating light (classic US heavy-duty control-station device; NEMA 3/3R/4/4X/12/13).

2. Part-number decode

  • Series: 10250T (Cutler-Hammer)
  • Panel cutout: 30.5mm

3. Compatibility & ordering

Eaton's M22 (RMQ-Titan, 22mm) and E30 / 10250T (30.5mm heavy-duty) are its principal command-switch ranges. This is a complete/integrated device. Match by size (22 / 30.5mm), function (pushbutton/selector/indicator/E-stop), color, illumination, and contact arrangement; cross-reference to Schneider Harmony, Allen-Bradley 800F/800T, Siemens 3SU, or IDEC HW by the same attributes if needed.

4. Data-quality note

The Eaton series, size, and component type are decoded from the part number (grounded in Eaton's Vol.7 catalog and distributor listings). The exact color and contact arrangement depend on the remaining digits and the sub-family — confirm against the Eaton datasheet for a precise order (not guessed here).

5. Sources

  • Eaton control-components catalog (Vol.7) / RMQ-Titan M22 & 10250T (eaton.com)
  • Distributor listing (Newark / Mouser) — search the exact part number

1 source
  1. Eaton — 10250T5B62-S112 — eaton.com

Specificații

Enriched by
eaton-decoder-2026-08-12
Lead time
21 Days
Manufacturer series
10250T (Cutler-Hammer)
Mouser part number
504-10250T5B62-S112
Panel cutout
30.5mm
Pn status
decoded
Rohs status
Series description
Eaton Cutler-Hammer 10250T 30.5mm HEAVY-DUTY pushbutton / indicating light (classic US heavy-duty control-station device; NEMA 3/3R/4/4X/12/13)

Referință rapidă de instalare

Panel cutout: 22mm. Mount with the yellow backing plate visible (required by EN/ISO 13850).

Wiring: Wire NC contacts in series with the safety relay input channels. Use dual-channel wiring for SIL 3 / PLe applications. Never wire directly to a motor contactor.

Testing: Press the e-stop and verify the machine stops within the required time. Test the reset mechanism. Repeat monthly per EN/ISO 13850.

Dimensiuni

Depanare

E-stop won't reset (twist/pull doesn't release)

Check for debris in the mechanism. For twist-release: turn clockwise 45-90 degrees. For push-pull: pull straight out firmly. If the mechanism is stuck, the internal latch may be damaged — replace the entire head assembly.

Machine doesn't stop when e-stop is pressed

Critical safety issue. Immediately lock out the machine. Check wiring — NC contacts must be in series with the safety relay. Verify the safety relay is functioning. A broken wire in an NC circuit should cause a stop, so check for a wiring bypass.

Safety relay faults after e-stop reset

The safety relay detects a cross-fault between the two monitoring channels. Check that both NC contacts on the e-stop are switching simultaneously. One contact may be welded closed — replace the contact block.

De unde cumpărați

Interval de preț

$523.45 — $523.45

la 1 distribuitori

Specificații rapide

Enriched by
eaton-decoder-2026-08-12
Lead time
21 Days
Manufacturer series
10250T (Cutler-Hammer)
Mouser part number
504-10250T5B62-S112
Panel cutout
30.5mm