51-259.0250

Activ

EAO 51-259.0250

EAO 51-259.0250 — EAO 51-259.0250

Emergency Stop Switches / E-Stop Switches

Research Notes

1. What this is

51-259.0250 is a EAO Series 51 command switch.

2. Part-number decode

  • Series: EAO Series 51
  • Type: command switch

3. Compatibility & ordering

EAO (Switzerland) makes premium modular HMI command switches — pushbuttons, indicators, selectors, and E-stops in numbered series (04/14/45/51/56/61/82/84). Match by type, actuation, illumination, sealing, and mounting, then use the manufacturer datasheet to confirm the exact contact and termination encoded in the part number.

4. Data-quality note

The EAO series and switch type are decoded from the part number (grounded in the manufacturer catalog and distributor listings). The exact contact arrangement, termination, and cap/colour are encoded in the full order code — confirm against the datasheet for a precise order (not guessed here).

5. Sources

  • EAO product catalog (eao.com)
  • Distributor listing (DigiKey / Mouser) — search the exact part number

1 source
  1. EAO — 51-259.0250 — eao.com

Specificații

Device class
command switch
Enriched by
eao-decoder-2026-08-12
Lead time
0 Days
Manufacturer series
Series 51
Mouser part number
123-51-259.0250
Pn status
decoded
Rohs status
Series description
EAO Series 51 — Swiss-made modular HMI command switch (pushbutton / illuminated pushbutton / indicator / selector / E-stop; operator + contact/LED elements assemble into a complete device)

Referință rapidă de instalare

Panel cutout: 22mm. Mount with the yellow backing plate visible (required by EN/ISO 13850).

Wiring: Wire NC contacts in series with the safety relay input channels. Use dual-channel wiring for SIL 3 / PLe applications. Never wire directly to a motor contactor.

Testing: Press the e-stop and verify the machine stops within the required time. Test the reset mechanism. Repeat monthly per EN/ISO 13850.

Dimensiuni

Depanare

E-stop won't reset (twist/pull doesn't release)

Check for debris in the mechanism. For twist-release: turn clockwise 45-90 degrees. For push-pull: pull straight out firmly. If the mechanism is stuck, the internal latch may be damaged — replace the entire head assembly.

Machine doesn't stop when e-stop is pressed

Critical safety issue. Immediately lock out the machine. Check wiring — NC contacts must be in series with the safety relay. Verify the safety relay is functioning. A broken wire in an NC circuit should cause a stop, so check for a wiring bypass.

Safety relay faults after e-stop reset

The safety relay detects a cross-fault between the two monitoring channels. Check that both NC contacts on the e-stop are switching simultaneously. One contact may be welded closed — replace the contact block.

De unde cumpărați

Interval de preț

$39.87 — $39.87

la 1 distribuitori

Specificații rapide

Device class
command switch
Enriched by
eao-decoder-2026-08-12
Lead time
0 Days
Manufacturer series
Series 51
Mouser part number
123-51-259.0250