1801869

Activ

Apem 1801869

Emergency Stop Switches / E-Stop Switches But. B/W Pr. Stop

Note de Cercetare

1. What this is

1801869 is an APEM APEM component — line not recognized.

2. Part-number decode

  • Series: APEM APEM (line not recognized)
  • Type: switch

3. Compatibility & ordering

APEM makes pushbuttons (incl. anti-vandal and illuminated), tactile switches, toggle switches, joysticks, and indicators for industrial and electronic equipment. Match by type, actuation, illumination, sealing (IP rating), and mounting, then use the APEM datasheet to confirm the exact contact and actuator configuration encoded in the part number.

4. Data-quality note

The exact APEM product line/configuration could not be confidently decoded from this part number. Kept and documented; flagged needs-verification.

5. Sources

  • APEM product catalog (apem.com)
  • Distributor listing (RS / Mouser / DigiKey) — search the exact part number

Sursă
  1. APEM — 1801869 — apem.com

Specificații

Enriched by
apem-decoder-2026-08-12
Lead time
77 Days
Manufacturer series
APEM (line not recognized)
Mouser part number
642-1801869
Pn status
needs-verification
Rohs status
RoHS Compliant
Series description
APEM switch component — exact product line/config could not be decoded from this part number; kept and flagged for verification rather than guessed

Referință rapidă de instalare

Panel cutout: 22mm. Mount with the yellow backing plate visible (required by EN/ISO 13850).

Wiring: Wire NC contacts in series with the safety relay input channels. Use dual-channel wiring for SIL 3 / PLe applications. Never wire directly to a motor contactor.

Testing: Press the e-stop and verify the machine stops within the required time. Test the reset mechanism. Repeat monthly per EN/ISO 13850.

Dimensiuni

Depanare

E-stop won't reset (twist/pull doesn't release)

Check for debris in the mechanism. For twist-release: turn clockwise 45-90 degrees. For push-pull: pull straight out firmly. If the mechanism is stuck, the internal latch may be damaged — replace the entire head assembly.

Machine doesn't stop when e-stop is pressed

Critical safety issue. Immediately lock out the machine. Check wiring — NC contacts must be in series with the safety relay. Verify the safety relay is functioning. A broken wire in an NC circuit should cause a stop, so check for a wiring bypass.

Safety relay faults after e-stop reset

The safety relay detects a cross-fault between the two monitoring channels. Check that both NC contacts on the e-stop are switching simultaneously. One contact may be welded closed — replace the contact block.

Specificații rapide

Enriched by
apem-decoder-2026-08-12
Lead time
77 Days
Manufacturer series
APEM (line not recognized)
Mouser part number
642-1801869
Pn status
needs-verification