EU2B-YB320FG-D

Active

IDEC EU2B-YB320FG-D

IDEC EU2B-YB320FG-D — IDEC EU2B-YB320FG-D

Series picture: the seller uses it for 11 other parts too, so it may not show this exact version.

Pushbutton Switches Haz Loc Pushbutton Type 4X

Research Notes

1. What this is

EU2B-YB320FG-D is an IDEC EU2B-series 30mm explosion-proof command device (fully sealed; ATEX / UL-NEC Class I Div 2, Type 4X) — e-stop / pushbutton / pilot for hazardous locations. This specific variant is Maintained (pushlock; turn or pull to reset).

2. Part-number decode

  • Series: IDEC EU2B — 30mm emergency-stop
  • Operation: Maintained (pushlock; turn or pull to reset)

3. Compatibility & ordering

Panel cutout: 30mm. Unibody construction — the operator and contact are a single assembly. Cross-reference by size, operation, contact arrangement, and color to an equivalent from another IEC command-switch line (Schneider Harmony, Allen-Bradley 800F/800T, Siemens 3SU, Eaton M22) if IDEC is unavailable.

4. Data-quality note

This page is generated by decoding IDEC's published part-number scheme for the EU2B series (grounded in IDEC's series datasheets and IDEC USA's catalog). The structured fields above follow directly from the code.

5. Sources

  • IDEC EU2B-series datasheet / ordering guide (idec.com)
  • IDEC USA catalog: https://us.idec.com (search the exact part number)

1 source
  1. IDEC USA catalog — EU2B-YB320FG-D — us.idec.com

Specifications

Device class
emergency-stop
Enriched by
idec-decoder-2026-08-12
Lead time
0 Days
Manufacturer series
EU2B
Modular
false
Mouser part number
199-EU2BYB320FGD
Operation
Maintained (pushlock; turn or pull to reset)
Panel cutout
30mm
Pn status
decoded
Rohs status
RoHS Compliant
Series description
IDEC EU2B-series 30mm explosion-proof command device (fully sealed; ATEX / UL-NEC Class I Div 2, Type 4X) — e-stop / pushbutton / pilot for hazardous locations

Installation Quick Reference

Panel cutout: 22mm. Insert from the front of the panel, secure with mounting nut from behind (tighten to 2-3 Nm).

Contact block: Snap or screw the contact block onto the rear of the button body. Ensure the contact block orientation matches the wiring diagram — NO terminals are usually marked.

Wiring: Use 0.5-2.5mm² stranded wire with ferrules. Tighten screw terminals to 0.8 Nm. Test the button function before energizing the circuit.

Dimensions

Troubleshooting

Button doesn't respond when pressed

Check the contact block first — it's the most common failure point. Test continuity across the NO or NC terminals with a multimeter. If no click is felt, the return spring in the head may be broken.

Works intermittently

Contact block contacts are pitted or burned. Replace the contact block — don't try to file the contacts. Check if the rated cycle count has been exceeded.

Button feels mushy or doesn't click

The spring return mechanism in the button head is worn. Replace the head. The contact block can usually be reused if it tests OK.

Photos & Drawings

Images: mouser.com

Quick Specs

Device class
emergency-stop
Enriched by
idec-decoder-2026-08-12
Lead time
0 Days
Manufacturer series
EU2B
Modular
false