4099-9001
Descontinuado4099-9001 MapNet II Addressable Pull Station
This product has been discontinued. Pesquisar alternativas.
Single-action addressable manual pull station with integral IAM module for Simplex IDNet/MapNet II fire alarm loops. Now discontinued — replaced by the 4099-9004.
Aplicações comuns
Mount to single-gang backbox. Wire to Simplex IDNet or MapNet II addressable loop. Single-action pull activates alarm. Key reset required after activation. NOTE: This model is discontinued. For new installations, use the replacement 4099-9004. Still found in many existing buildings — maintenance techs should stock spares while available.
Notas de Pesquisa
1. Overview
The Simplex 4099-9001 is an addressable single-action manual fire-alarm pull station (manual call point) from Simplex (Johnson Controls). Single-action means one motion — pull the handle down — to initiate an alarm. It's individually addressable on Simplex's MapNet II / IDNet SLC (each station reports its own address to the panel), red thermoplastic, mounts to a single-gang backbox, and operates at up to 32 V DC on the loop. The -9001CB variant is the bilingual (English/French) version.
2. User Sentiment
A standard, widely-installed Simplex manual station — valued for the familiar look/feel, individual addressability (pinpoints which station was pulled), and Simplex-ecosystem integration. As life-safety hardware there's no consumer "sentiment"; the considerations are panel/protocol compatibility (MapNet II vs IDNet), addressing, and the reset/key needed after activation.
3. Real-World Applications
Manual fire-alarm activation at building exits and along egress paths — pull the handle to trigger the alarm; the addressable station tells the Simplex panel exactly which device operated (for fast location).
4. Technical Specifications
- Type: single-action manual pull station (manual call point) — pull down to activate
- Addressing: individually addressable, Simplex MapNet II / IDNet SLC
- Voltage: up to 32 V DC (loop)
- Housing: red thermoplastic
- Mounting: single-gang backbox
- Approvals: UL listed
- Variant: -9001CB = bilingual (EN/FR)
5. Ordering & Compatibility
For Simplex fire-alarm panels supporting MapNet II / IDNet addressable devices. Confirm the panel/protocol, addressing, and whether the bilingual (CB) or double-action variant is required. Reset typically needs the Simplex key after a pull. A genuine manual station (button/call point) — distinct from monitor/control modules.
6. Known Issues
No notable reliability issues — standard life-safety hardware. Practical care: verify panel protocol compatibility (MapNet II vs IDNet) and addressing, ensure the correct single- vs double-action and language variant, and follow proper testing/reset procedures.
Fonte
Especificações
|
Certifications
Third-party safety certifications. UL = required for US NEC installations. CE = EU compliance. CSA = Canadian standards.
|
UL
|
|
Color
Button/actuator color. Green = start/go, Red = stop/emergency, Yellow = caution, Blue = reset (per IEC 60204-1).
|
Red
|
|
Device type
|
Addressable single-action manual pull station (manual call point; pull-down)
|
|
Material
The bezel/body material. Metal bezels are more durable in harsh environments. Plastic is lighter and cheaper.
|
Thermoplastic
|
|
Mounting Type
How the button attaches to the panel. Panel mount is standard — installs through a cutout from the front.
|
Single-gang backbox
|
|
Protocol
The wireless communication standard. BLE = short range, phone direct. Zigbee = mesh network, needs hub. Z-Wave = mesh, needs hub. WiFi = direct, higher power.
|
Simplex MapNet II / IDNet addressable SLC
|
|
Type
|
Single-action
|
|
Variant note
|
-9001CB = bilingual EN/FR
|
|
Max Voltage
|
32V DC
|
Referência rápida de instalação
Panel cutout: 22mm. Standard panel mounting — insert from front, secure from behind.
Dimensões
Solução de problemas
Not responding to input
Check wiring continuity with a multimeter. Verify the contact block is properly seated. Inspect terminals for loose connections.
Onde comprar
Nenhum registro de distribuidor disponível ainda.
Especificações rápidas
- Certifications
- UL
- Color
- Red
- Device type
- Addressable single-action manual pull station (manual call point; pull-down)
- Material
- Thermoplastic
- Mounting Type
- Single-gang backbox
O que os usuários dizem
“Solid Simplex product, widely available and well-documented.”