XALD211
AktywnyHarmony XALD 2-Button Start/Stop Station
Schneider XALD 2-button station — green start + red stop in one enclosure.
Typowe Zastosowania
The most common control station in the world. Green start (1NO) and red stop (1NC) in a single IP66 sealed enclosure. Mount on a wall or machine frame. Pre-wired with cable glands. Found on millions of motor starters, pump stations, and conveyor lines globally. One part number = complete start/stop station.
Kompatybilność
Uses standard XB4/XB5 buttons and contact blocks internally. Buttons can be individually replaced if needed.
Specyfikacje
|
Certifications
Third-party safety certifications. UL = required for US NEC installations. CE = EU compliance. CSA = Canadian standards.
|
UL, CSA, CE
|
|
Color
Button/actuator color. Green = start/go, Red = stop/emergency, Yellow = caution, Blue = reset (per IEC 60204-1).
|
Green + Red
|
|
Contact Configuration
1NO + 1NC: One circuit closes and one opens when pressed. Common for start buttons that also signal 'running' state.
|
1NO + 1NC
|
|
IP Rating
IP66: Dust-tight and withstands powerful water jets from any direction. Standard for outdoor and washdown applications.
|
IP66
|
|
Material
The bezel/body material. Metal bezels are more durable in harsh environments. Plastic is lighter and cheaper.
|
Polycarbonate
|
|
Mounting Type
How the button attaches to the panel. Panel mount is standard — installs through a cutout from the front.
|
Surface mount (enclosed)
|
Skrócona Instrukcja Montażu
Panel cutout: 22mm. Insert from the front of the panel, secure with mounting nut from behind (tighten to 2-3 Nm).
Contact block: Snap or screw the contact block onto the rear of the button body. Ensure the contact block orientation matches the wiring diagram — NO terminals are usually marked.
Wiring: Use 0.5-2.5mm² stranded wire with ferrules. Tighten screw terminals to 0.8 Nm. Test the button function before energizing the circuit.
Wymiary
Schemat Połączeń
Rozwiązywanie Problemów
Button doesn't respond when pressed
Check the contact block first — it's the most common failure point. Test continuity across the NO or NC terminals with a multimeter. If no click is felt, the return spring in the head may be broken.
Works intermittently
Contact block contacts are pitted or burned. Replace the contact block — don't try to file the contacts. Check if the rated cycle count has been exceeded.
Button feels mushy or doesn't click
The spring return mechanism in the button head is worn. Replace the head. The contact block can usually be reused if it tests OK.
Gdzie Kupić
Przedział cenowy
$73.92 — $179.53
u 2 dystrybutorów
Skrócone Specyfikacje
- Certifications
- UL, CSA, CE
- Color
- Green + Red
- Contact Configuration
- 1NO + 1NC
- IP Rating
- IP66
- Material
- Polycarbonate
Co Mówią Użytkownicy
“The most common control station in the world. Green start (1NO) and red stop (1NC) in a single IP66 sealed enclosure. Mount on a wall or machine frame. Pre-wired with cable glands. Found on millions o”
Dowiedz się Więcej
Objaśnienie Klasyfikacji IP
Co oznaczają IP65, IP66, IP67, IP69K dla Państwa zastosowania
Przewodnik 22mm vs 30mm
Jakiego rozmiaru otworu montażowego potrzebujesz?
Bloki Styków: NO vs NC
Jak wybrać i podłączyć bloki styków
Narzędzie Wyszukiwania Przycisków
Znajdź właściwy przycisk wg typu, rozmiaru i koloru