M22-DDL-YR-K7
AktywnyM22 Yellow/Red Double Illuminated Button
Eaton M22 double-actuator yellow/red illuminated.
Typowe Zastosowania
Dual button: yellow (jog/test) on top, red (stop) on bottom. Both illuminated. Saves panel space in compact control stations.
Specyfikacje
|
Certifications
Third-party safety certifications. UL = required for US NEC installations. CE = EU compliance. CSA = Canadian standards.
|
UL, CSA, CE
|
|
Color
Button/actuator color. Green = start/go, Red = stop/emergency, Yellow = caution, Blue = reset (per IEC 60204-1).
|
Yellow/Red dual
|
|
Contact Configuration
1NO + 1NC: One circuit closes and one opens when pressed. Common for start buttons that also signal 'running' state.
|
1NO + 1NC
|
|
Cutout Diameter
The hole size you drill in your panel to mount this button. 22mm is the most common industrial standard worldwide.
|
22.5mm
|
|
Illumination
Whether the button has a built-in light. Illuminated buttons show status (lit = active).
|
Dual LED
|
|
IP Rating
IP67: Dust-tight and survives temporary water submersion (1m for 30 min). Handles oil splashes, steam cleaning, and rain.
|
IP67 (front)
|
|
LED Voltage
The voltage required for the built-in LED. Must match your control circuit voltage (typically 24V DC or 230V AC).
|
24V AC/DC
|
|
Series
The manufacturer's product family. Products in the same series share mounting systems and accessories.
|
M22
|
Skrócona Instrukcja Montażu
Panel cutout: 22.5mm. Insert from the front of the panel, secure with mounting nut from behind (tighten to 2-3 Nm).
Contact block: Snap or screw the contact block onto the rear of the button body. Ensure the contact block orientation matches the wiring diagram — NO terminals are usually marked.
Wiring: Use 0.5-2.5mm² stranded wire with ferrules. Tighten screw terminals to 0.8 Nm. Test the button function before energizing the circuit.
Wymiary
Schemat Połączeń
Rozwiązywanie Problemów
Button doesn't respond when pressed
Check the contact block first — it's the most common failure point. Test continuity across the NO or NC terminals with a multimeter. If no click is felt, the return spring in the head may be broken.
Works intermittently
Contact block contacts are pitted or burned. Replace the contact block — don't try to file the contacts. Check if the rated cycle count has been exceeded.
Button feels mushy or doesn't click
The spring return mechanism in the button head is worn. Replace the head. The contact block can usually be reused if it tests OK.
Gdzie Kupić
Przedział cenowy
$0.05 — $33.13
u 2 dystrybutorów
Skrócone Specyfikacje
- Certifications
- UL, CSA, CE
- Color
- Yellow/Red dual
- Contact Configuration
- 1NO + 1NC
- Cutout Diameter
- 22.5mm
- Illumination
- Dual LED
Co Mówią Użytkownicy
“Dual button: yellow (jog/test) on top, red (stop) on bottom. Both illuminated. Saves panel space in compact control stations.”
Dowiedz się Więcej
Objaśnienie Klasyfikacji IP
Co oznaczają IP65, IP66, IP67, IP69K dla Państwa zastosowania
Przewodnik 22mm vs 30mm
Jakiego rozmiaru otworu montażowego potrzebujesz?
Bloki Styków: NO vs NC
Jak wybrać i podłączyć bloki styków
Narzędzie Wyszukiwania Przycisków
Znajdź właściwy przycisk wg typu, rozmiaru i koloru