P2AP6

Aktywny

Altech P2AP6

Altech P2AP6 — Altech P2AP6

Zdjęcie serii: sprzedawca używa go również dla 3 innych części, więc może nie pokazywać dokładnie tej wersji.

Switch Actuators Push Button Oper., 22 mm,

Notatki Badawcze

1. What this is

P2AP6 is an Altech 2AP-series 22mm flush pushbutton operator.

2. Part-number decode

  • Series: Altech 2AP

3. Compatibility & ordering

Altech 22/30mm pushbuttons are cost-effective IEC-style panel operators. Match by size (22mm), operator material (metal vs plastic), illumination (and voltage), action, and contact blocks; cross-reference to Schneider Harmony, Allen-Bradley 800F, Siemens 3SU, or Eaton M22 by the same attributes if needed.

4. Data-quality note

The Altech series family is identified, but the exact operator style/contact config is not fully determinable from the part number alone — treat as indicative and confirm against Altech's datasheet. Flagged decoded-partial.

5. Sources

  • Altech Corp datasheet / 22mm pushbutton tech specs (altechcorp.com)
  • Distributor listing (Mouser / Future Electronics) — search the exact part number

Źródło
  1. Altech Corp — P2AP6 — altechcorp.com

Specyfikacje

Device class
pushbutton
Enriched by
altech-decoder-2026-08-12
Lead time
0 Days
Manufacturer series
2AP
Mouser part number
845-P2AP6
Pn status
decoded-partial
Rohs status
Series description
Altech 2AP-series 22mm flush pushbutton operator

Skrócona Instrukcja Montażu

Panel cutout: 22mm. Insert from the front of the panel, secure with mounting nut from behind (tighten to 2-3 Nm).

Contact block: Snap or screw the contact block onto the rear of the button body. Ensure the contact block orientation matches the wiring diagram — NO terminals are usually marked.

Wiring: Use 0.5-2.5mm² stranded wire with ferrules. Tighten screw terminals to 0.8 Nm. Test the button function before energizing the circuit.

Wymiary

Rozwiązywanie Problemów

Button doesn't respond when pressed

Check the contact block first — it's the most common failure point. Test continuity across the NO or NC terminals with a multimeter. If no click is felt, the return spring in the head may be broken.

Works intermittently

Contact block contacts are pitted or burned. Replace the contact block — don't try to file the contacts. Check if the rated cycle count has been exceeded.

Button feels mushy or doesn't click

The spring return mechanism in the button head is worn. Replace the head. The contact block can usually be reused if it tests OK.

Zdjęcia i Rysunki

Zdjęcia: mouser.com

Skrócone Specyfikacje

Device class
pushbutton
Enriched by
altech-decoder-2026-08-12
Lead time
0 Days
Manufacturer series
2AP
Mouser part number
845-P2AP6