시리즈 사진: 판매자가 이를 2개의 다른 부품에도 사용하므로 정확히 이 버전을 보여주지 않을 수 있습니다.
Emergency Stop Switches / E-Stop Switches Start/Stop Dual Illum Icon, 24mm
연구 노트
1. What this is
FDAP1F1482F03 is an APEM pushbutton.
2. Part-number decode
- Series: APEM pushbutton
- Type: pushbutton
3. Compatibility & ordering
APEM makes pushbuttons (incl. anti-vandal and illuminated), tactile switches, toggle switches, joysticks, and indicators for industrial and electronic equipment. Match by type, actuation, illumination, sealing (IP rating), and mounting, then use the APEM datasheet to confirm the exact contact and actuator configuration encoded in the part number.
4. Data-quality note
The APEM product line/type is identified; the detailed configuration is left to the datasheet rather than guessed. Flagged decoded-partial.
5. Sources
- APEM product catalog (apem.com)
- Distributor listing (RS / Mouser / DigiKey) — search the exact part number
출처
- APEM — FDAP1F1482F03 — apem.com
사양 목록
|
Device class
|
pushbutton
|
|
Enriched by
|
apem-decoder-2026-08-12
|
|
Lead time
|
70 Days
|
|
Manufacturer series
|
pushbutton
|
|
Mouser part number
|
642-FDAP1F1482F03
|
|
Pn status
|
decoded-partial
|
|
Rohs status
|
RoHS Compliant
|
|
Series description
|
APEM pushbutton switch (PBAR / ES / FDAP series panel pushbutton or component)
|
설치 빠른 참조
Panel cutout: 22mm. Mount with the yellow backing plate visible (required by EN/ISO 13850).
Wiring: Wire NC contacts in series with the safety relay input channels. Use dual-channel wiring for SIL 3 / PLe applications. Never wire directly to a motor contactor.
Testing: Press the e-stop and verify the machine stops within the required time. Test the reset mechanism. Repeat monthly per EN/ISO 13850.
외형 치수
문제 해결
E-stop won't reset (twist/pull doesn't release)
Check for debris in the mechanism. For twist-release: turn clockwise 45-90 degrees. For push-pull: pull straight out firmly. If the mechanism is stuck, the internal latch may be damaged — replace the entire head assembly.
Machine doesn't stop when e-stop is pressed
Critical safety issue. Immediately lock out the machine. Check wiring — NC contacts must be in series with the safety relay. Verify the safety relay is functioning. A broken wire in an NC circuit should cause a stop, so check for a wiring bypass.
Safety relay faults after e-stop reset
The safety relay detects a cross-fault between the two monitoring channels. Check that both NC contacts on the e-stop are switching simultaneously. One contact may be welded closed — replace the contact block.
주요 사양
- Device class
- pushbutton
- Enriched by
- apem-decoder-2026-08-12
- Lead time
- 70 Days
- Manufacturer series
- pushbutton
- Mouser part number
- 642-FDAP1F1482F03